期刊论文详细信息
BMC Oral Health
Stress distribution and fracture resistance of green reprocessed polyetheretherketone (PEEK) single implant crown restorations compared to unreprocessed PEEK and Zirconia: an in-vitro study
Research
Marwa Emam1  Ahmed Mohamed Arafa2 
[1] Fixed Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity St, El-Qobba Bridge, Al Waili, 11566, Cairo, Egypt;Fixed Prosthodontics Department, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt;
关键词: Green dentistry;    PEEK reprocessing;    Zirconia;    Dental implant;    Heat pressing;    Fracture resistance;    Stress;    Strain;    Modulus of elasticity;   
DOI  :  10.1186/s12903-023-02943-x
 received in 2023-01-26, accepted in 2023-04-05,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundIt is unclear which crown materials are optimum to disperse the generated stresses around dental implants. The objective of this study is to assess stress distribution and fracture resistance of green reprocessed Polyetheretherketone (PEEK) in comparison to un-reprocessed PEEK and zirconia single implant crown restorations.MethodsTwenty crowns (n = 20) were obtained, five from zirconia and fifteen from pressed PEEK that were subdivided into 3 groups of five specimens each (n = 5) according to weight% of reprocessed material used. A 100% new PEEK was used for the first group, 50% new and 50% reprocessed PEEK were used for the second group, and a 100% reprocessed PEEK was used for the third group. Epoxy resin model with dental implant in the second mandibular premolar was constructed with strain gauges located mesially and distally to the implant to record strain while a load of 100 N was applied with 0.5 mm/min then specimens of all groups were vertically loaded till failure in a universal testing machine at cross head speed 1 mm/min. Data was statistically analyzed by using One-way Analysis of Variance (ANOVA) followed by Post-hoc test when ANOVA test is significant.ResultsNo significant difference between strain values of tested groups (p = 0.174) was noticed. However, a significant difference between fracture resistance values was noticed where the zirconia group recorded a significantly higher value (p < 0.001).ConclusionsImplant restorative materials with different moduli of elasticity have similar effects regarding stresses distributed through dental implant and their surrounding bone. Reprocessed PEEK implant restorations transmit similar stresses to dental implant and surrounding bone as non-reprocessed PEEK and zirconia restorations. Zirconia failed at higher load values than all tested PEEK restorations but all can be safely used in the posterior area as crown restorations for single implants.Clinical relevanceApplying “green dentistry” principles may extend to include reprocessing of pressed PEEK restorative materials without affecting the material’s shock absorption properties.

【 授权许可】

CC BY   
© The Author(s) 2023

【 预 览 】
附件列表
Files Size Format View
RO202308151535589ZK.pdf 1187KB PDF download
41116_2023_36_Article_IEq17.gif 1KB Image download
41116_2023_36_Article_IEq70.gif 1KB Image download
41116_2023_36_Article_IEq72.gif 1KB Image download
【 图 表 】

41116_2023_36_Article_IEq72.gif

41116_2023_36_Article_IEq70.gif

41116_2023_36_Article_IEq17.gif

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  文献评价指标  
  下载次数:8次 浏览次数:7次