Nuclear Fushion | |
Limiter observations during W7-X first plasmas | |
article | |
G.A. Wurden1  C. Biedermann2  F. Effenberg3  M. Jakubowski2  H. Niemann2  L. Stephey3  S. Bozhenkov2  S. Brezinsek5  J. Fellinger2  B. Cannas6  F. Pisano6  S. Marsen2  H.P. Laqua2  R. König2  O. Schmitz3  J.H. Harris7  E.A. Unterberg7  the W7-X Team2  | |
[1] Los Alamos National Laboratory;Max Planck Institut für Plasmaphysik;University of Wisconsin;University of Szczecin, Institute of Physics;Forschungszentrum Jülich GmbH;University of Cagliari, Via Universita 40;Oak Ridge National Laboratory | |
关键词: W7-X; stellarator; infrared; heat loads; limiter; | |
DOI : 10.1088/1741-4326/aa6609 | |
来源: Institute of Physics Publishing Ltd. | |
【 摘 要 】
During the first operational phase (referred to as OP1.1) of the new Wendelstein 7-X (W7-X) stellarator, five poloidal graphite limiters were mounted on the inboard side of the vacuum vessel, one in each of the five toroidal modules which form the W7-X vacuum vessel. Each limiter consisted of nine specially shaped graphite tiles, designed to conform to the last closed field line geometry in the bean-shaped section of the standard OP1.1 magnetic field configuration (Sunn Pedersenet al2015Nucl. Fusion55126001). We observed the limiters with multiple infrared and visible camera systems, as well as filtered photomultipliers. Power loads are calculated from infrared (IR) temperature measurements using THEODOR, and heating patterns (dual stripes) compare well with field line mapping and EMC3-EIRENE predictions. While the poloidal symmetry of the heat loads was excellent, the toroidal heating pattern showed up to a factor of 2 × variation, with peak heat loads on Limiter 1. The total power intercepted by the limiters was up to ~60% of the input ECRH heating power. Calorimetry using bulk tile heating (measured via post-shot IR thermography) on Limiter 3 showed a difference between short high power discharges, and longer lower power ones, with regards to the fraction of energy deposited on the limiters. Finally, fast heating transients, with frequency >1 kHz were detected, and their visibility was enhanced by the presence of surface coatings which developed on the limiters by the end of the campaign.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202307170000045ZK.pdf | 5146KB | download |