期刊论文详细信息
Indian Journal of Chemical Technology
Defluoridation of water by electrocoagulation using aluminium electrode
article
Neeraj Chandraker1  Parmesh Kumar Chaudhari2  Ghoshna Jyoti1  Raghwendra Singh Thakur1 
[1] Department of Chemical Engineering, Guru Ghasidas Vishwavidyalaya ,(A Central University) Bilaspur;Department of Chemical Engineering, National Institute of Technology
关键词: Current density;    Electrocoagulation;    Fluoride reduction;    Kinetic;    Synthetic water study;    Article;   
DOI  :  10.56042/ijct.v29i5.62186
学科分类:化学(综合)
来源: National Institute of Science Communication and Information Resources
PDF
【 摘 要 】

Fluoride (Fˉ) has been removed successfully removal from laboratory prepared fluoride water solution through electrocoagulation using Aluminium (Al) electrode. Consequence of parameters such as pH, current density (CD), initial mass of Fˉ and treatment hour are analyzed over Fˉ removal. The maximum defluoridation of 85.2% occurred at pH 6.5, CD 34.72 A/m2 (1A) and contact time of 50 min for starting Fˉ concentration of 50 mg/L in the solution. The kinetic study has been performed to explore the mechanism of electrocoagulation technique, disclosed that the order of the reaction was in the span 2.0-2.07 and 0.05 for fluoride concentration and current density, respectively. This study shows that electrocoagulation using Al electrode has good potential for fluoride removal.

【 授权许可】

CC BY-NC-ND   

【 预 览 】
附件列表
Files Size Format View
RO202307160002413ZK.pdf 6683KB PDF download
  文献评价指标  