Indian Journal of Pure & Applied Physics | |
A Study of Radon Concentration in Drinking Water of Lolab valley, Kashmir Himalaya | |
article | |
Mohammad Rafiq Chakan1  Sajad Masood1  Salik Nazir1  Mehak Mohi u Din1  Amit Kumar Singla2  Supriya Rani2  Shakeel Simnani1  | |
[1] Department of Physics, University of Kashmir;Department of Physics, Maharaja Ranjit Singh Punjab Technical University | |
关键词: Drinking water samples; Smart Radon Monitor; Radon concentration; Inhalation dose; Lolab Kashmir; Article; | |
DOI : 10.56042/ijpap.v61i6.2433 | |
来源: National Institute of Science Communication and Information Resources | |
【 摘 要 】
In the present study, radon concentration has been estimated in drinking water samples of different locations of Lolab in Kupwara district of Kashmir valley. A scintillation based detector, (Smart RnDuo) has been used to evaluate the radon concentration in collected drinking water samples. In addition, the surface contamination of gamma radiations at each location was detected using portable gamma ray detector (PM 1405, Polimaster Inc., USA). The radon concentration in drinking water samples has been found to vary from 3.27 to 59.50 BqL−1, with an average of 23.65 BqL-1.The annual inhalation dose varied from 0.01 to 0.15 mSvy-1. The average annual inhalation dose was found to be 0.06 mSvy-1 and it lies well within the permissible limits.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202307160002285ZK.pdf | 918KB | download |