Građevinar | |
Shear breakout capacity of various fastening systems in concrete elements | |
article | |
Natalija Bede1  Philipp Grosser2  Joško Ožbolt3  | |
[1] University of Rijeka Faculty of Civil Engineering;Hilti;University of Stuttgart Institute for Building Materials | |
关键词: fastening systems; failure due to concrete fracturing; shear load; experimental testing; design recommendations; | |
DOI : 10.14256/JCE.2168.2017 | |
学科分类:社会科学、人文和艺术(综合) | |
来源: Hrvatsko Drustvo Gradevinskih Inzenjera | |
【 摘 要 】
The results of a test program carried out to investigate the difference in the concrete breakout capacity of various fastening systems installed parallel to the edge of a concrete member, and loaded in shear towards the edge of the concrete member, are presented and analysed. According to the current design recommendations, the calculated concrete breakout capacity of anchor channels yields to a lower failure capacity compared to headed anchors. Welded anchors (headed anchors welded to a steel plate) and bonded anchors are also tested. Based on the test results, various fastening systems in concrete elements are compared.
【 授权许可】
CC BY
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202307150003844ZK.pdf | 542KB | download |