| Građevinar | |
| Shear connection with groups of headed studs | |
| article | |
| Milan Spremić1  Zlatko Marković1  Jelena Dobrić1  Milan Veljković2  Dragan Budjevac1  | |
| [1] University of Belgrad, Faculty of Civil Eng;Technical University of Delft, Faculty of Civil Engineering and Geodesy | |
| 关键词: shear connection; groups of headed studs; composite prefabricate beams; | |
| DOI : 10.14256/JCE.1701.2016 | |
| 学科分类:社会科学、人文和艺术(综合) | |
| 来源: Hrvatsko Drustvo Gradevinskih Inzenjera | |
PDF
|
|
【 摘 要 】
The behaviour and characteristics of the elements of prefabricated composite steel and concrete structures are determined by behaviour of the longitudinal shear connection. Headed studs in groups are most frequently used for forming longitudinal shear connection of prefabricated composite beams. The results of experimental research and advanced numerical models of shear connections, obtained using groups of headed studs, are presented in the paper. When headed studs are arranged in groups, it is recommended to use the headed studs with the height greater than the 4d height prescribed by the Eurocode.
【 授权许可】
CC BY
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202307150003806ZK.pdf | 827KB |
PDF