期刊论文详细信息
International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering
Performance Analysis of Multi-MachineSystem Using UPFC
article
P.R. Sharma1  Rajesh Kr. Ahuja1  Shakti Vashisth1 
[1] Department of Electrical Engineering, YMCAUST
关键词: CPF;    FACTS;    FVSI;    L- Index;    PSAT;    Stability;    UPFC;   
来源: Research & Reviews
PDF
【 摘 要 】

In this paper best location of UPFC placement is identified on the basis of maximum loadability of a system. Simulation is done by using standard data of IEEE-14 bus system. Load reactance is increased by 5 %, 10 %, 15%, 20%, 25%, 30%, 35%, and 40%. Voltage stability index namely L-INDEX and FVSI is calculated at each percentage change in reactive load. Weakest line, the line at which voltage stability index has highest value and lower value of voltage, is measured using voltage stability index. UPFC is placed onthe most critical line which improves the voltage stability and minimizes the losses in the transmission system.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO202307140001743ZK.pdf 3664KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:3次