Bone & Joint Research | |
Limb position influences component orientation in Oxford mobile bearing unicompartmental knee arthroplasty: an experimental cadaveric study | |
article | |
Sachin Tapasvi1  Anshu Shekhar1  Shantanu Patil2  Hemant Pandit3  | |
[1] The Orthopaedic Speciality Clinic;Translational Medicine & Research, SRM Medical College and Hospitals, SRM University;University of Leeds | |
关键词: Knee; Osteoarthritis; Arthroplasty; Patient positioning; Kinematics; Unicompartmental Knee Arthroplasty; Mobile bearing; Kinematics; Implantation; Spatial orientation; | |
DOI : 10.1302/2046-3758.96.BJR-2019-0258.R1 | |
学科分类:骨科学 | |
来源: British Editorial Society Of Bone And Joint Surgery | |
【 摘 要 】
AimsThe mobile bearing Oxford unicompartmental knee arthroplasty (OUKA) is recommended to be performed with the leg in the hanging leg (HL) position, and the thigh placed in a stirrup. This comparative cadaveric study assesses implant positioning and intraoperative kinematics of OUKA implanted either in the HL position or in the supine leg (SL) position.MethodsA total of 16 fresh-frozen knees in eight human cadavers, without macroscopic anatomical defects, were selected. The knees from each cadaver were randomized to have the OUKA implanted in the HL or SL position.ResultsTibial base plate rotation was significantly more variable in the SL group with 75% of tibiae mal-rotated. Multivariate analysis of navigation data found no difference based on all kinematic parameters across the range of motion (ROM). However, area under the curve analysis showed that knees placed in the HL position had much smaller differences between the pre- and post-surgery conditions for kinematics mean values across the entire ROM.ConclusionThe sagittal tibia cut, not dependent on standard instrumentation, determines the tibial component rotation. The HL position improves accuracy of this step compared to the SL position, probably due to better visuospatial orientation of the hip and knee to the surgeon. The HL position is better for replicating native kinematics of the knee as shown by the area under the curve analysis. In the supine knee position, care must be taken during the sagittal tibia cut, while checking flexion balance and when sizing the tibial component.
【 授权许可】
CC BY-NC
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202307110000571ZK.pdf | 479KB | download |