期刊论文详细信息
Bone & Joint Research
Medial migration in cephalomedullary nail fixation of pertrochanteric hip fractures: A biomechanical analysis using a novel bidirectional cyclic loading model
article
G. W. Law1  Y. R. Wong2  A. K-S. Yew1  A. C. T. Choh1  J. S. B. Koh1  T. S. Howe1 
[1] Department of Orthopaedic Surgery, Singapore General Hospital;Singapore General Hospital
关键词: Medial migration;    Pertrochanteric hip fractures;    Intramedullary nail;    Cephalomedullary nail;    Hip fractures;   
DOI  :  10.1302/2046-3758.87.BJR-2018-0271.R1
学科分类:骨科学
来源: British Editorial Society Of Bone And Joint Surgery
PDF
【 摘 要 】

ObjectivesThe paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling.MethodsA total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles.ResultsThe MMDs for Groups 1, 2, and 3 were 1.02 mm, 6.27 mm, and 5.44 mm respectively, with reliable reproduction of medial migration seen in all groups. Bidirectional loading groups showed significantly higher MMDs compared with the unidirectional loading group (p < 0.01).ConclusionOur results demonstrate significant contributions of bidirectional cyclic loading to the medial migration phenomenon in cephalomedullary nail fixation of pertrochanteric hip fractures.

【 授权许可】

CC BY-NC   

【 预 览 】
附件列表
Files Size Format View
RO202307110000504ZK.pdf 2245KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:0次