The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty
article
R. M. Cowie1  S. S. Aiken2  J. J. Cooper2  L. M. Jennings1 
[1] Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds;Biocomposites Ltd
关键词: Biotribology;    Ultra-high-molecular-weight polyethylene (UHMWPE);    Knee arthroplasty;    Bone void filler;    Calcium sulphate;   
DOI  :  10.1302/2046-3758.82.BJR-2018-0146.R1
学科分类:骨科学
来源: British Editorial Society Of Bone And Joint Surgery
PDF
【 摘 要 】

ObjectivesBone void fillers are increasingly being used for dead space management in arthroplasty revision surgery. The aim of this study was to investigate the influence of calcium sulphate bone void filler (CS-BVF) on the damage and wear of total knee arthroplasty using experimental wear simulation.MethodsA total of 18 fixed-bearing U2 total knee arthroplasty system implants (United Orthopedic Corp., Hsinchu, Taiwan) were used. Implants challenged with CS-BVF were compared with new implants (negative controls) and those intentionally scratched with a diamond stylus (positive controls) representative of severe surface damage (n = 6 for each experimental group). Three million cycles (MC) of experimental simulation were carried out to simulate a walking gait cycle. Wear of the ultra-high-molecular-weight polyethylene (UHMWPE) tibial inserts was measured gravimetrically, and damage to articulating surfaces was assessed using profilometry.Results  0.05) between the wear rate of implants challenged with CS-BVF (3.3 mm3/MC (95% confidence interval (CI) 1.8 to 4.8)) and the wear rate of those not challenged (2.8 mm3/MC (95% CI 1.3 to 4.3)). However, scratching the cobalt-chrome (CoCr) significantly (p < 0.001) increased the wear rate (20.6 mm3/MC (95% CI 15.5 to 25.7)). The mean surface roughness of implants challenged with CS-BVF was equivalent to negative controls both after damage simulation (p = 0.98) and at the conclusion of the study (p = 0.28).ConclusionWhen used close to articulating surfaces, a low-hardness, high-purity CS-BVF had no influence on wear. When trapped between the articulating surfaces of a total knee arthroplasty, CS-BVF did not scratch the surface of CoCr femoral components, nor did it increase the wear of UHMWPE tibial inserts compared with undamaged negative controls.

【 授权许可】

CC BY-NC   

【 预 览 】
附件列表
Files Size Format View
RO202307110000474ZK.pdf 720KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:2次