期刊论文详细信息
Bone & Joint Research
Comparison of the stability of three fixation techniques between porous metal acetabular components and augments
article
N. A. Beckmann1  R. G. Bitsch2  M. Gondan3  M. Schonhoff4  S. Jaeger5 
[1] Oncologic Orthopaedics and Septic Orthopaedic Surgery, Heidelberg University Hospital;Clinical Coordinator of Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital;Faculty of Psychology, University of Vienna;Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital;Laboratory of Biomechanics and Implant Research, Clinic for Orthopaedics and Trauma Surgery, Heidelberg University Hospital
关键词: Revision hip arthroplasty;    Hip arthroplasty;    Acetabular revision;    Primary stability;    Porous metal;   
DOI  :  10.1302/2046-3758.74.BJR-2017-0198.R1
学科分类:骨科学
来源: British Editorial Society Of Bone And Joint Surgery
PDF
【 摘 要 】

ObjectivesIn order to address acetabular defects, porous metal revision acetabular components and augments have been developed, which require fixation to each other. The fixation technique that results in the smallest relative movement between the components, as well as its influence on the primary stability with the host bone, have not previously been determined.MethodsA total of 18 composite hemipelvises with a Paprosky IIB defect were implanted using a porous titanium 56 mm multihole acetabular component and 1 cm augment. Each acetabular component and augment was affixed to the bone using two screws, while the method of fixation between the acetabular component and augment varied for the three groups of six hemipelvises: group S, screw fixation only; group SC, screw plus cement fixation; group C, cement fixation only. The implanted hemipelvises were cyclically loaded to three different loading maxima (0.5 kN, 0.9 kN, and 1.8 kN).ResultsScrew fixation alone resulted in up to three times more movement (p = 0.006), especially when load was increased to 100% (p < 0.001), than with the other two fixation methods (C and SC). No significant difference was noted when a screw was added to the cement fixation. Increased load resulted in increased relative movement between the interfaces in all fixation methods (p < 0.001).ConclusionCement fixation between a porous titanium acetabular component and augment is associated with less relative movement than screw fixation alone for all implant interfaces, particularly with increasing loads. Adding a screw to the cement fixation did not offer any significant advantage. These results also show that the stability of the tested acetabular component/augment interface affects the stability of the construct that is affixed to the bone.

【 授权许可】

CC BY-NC   

【 预 览 】
附件列表
Files Size Format View
RO202307110000420ZK.pdf 922KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:1次