期刊论文详细信息
PeerJ
Validation of ultrasonographic muscle thickness measurements as compared to the gold standard of computed tomography in dogs
article
Lindsey E. Bullen1  Maria G. Evola1  Emily H. Griffith2  Gabriela S. Seiler1  Korinn E. Saker1 
[1]College of Veterinary Medicine: Department of Molecular Biomedical Sciences, North Carolina State University
[2]College of Sciences: Department of Statistics, North Carolina State University
关键词: Nutrition;    Muscle loss;    Ultrasound;    Computed tomography;    Canine;    Veterinary;    Dog;    Muscle thickness;    Monitoring;    DEXA;   
DOI  :  10.7717/peerj.2926
学科分类:社会科学、人文和艺术(综合)
来源: Inra
PDF
【 摘 要 】
ObjectiveThe objective was to quantitatively evaluate the validity of ultrasonographic (US) muscle measurements as compared to the gold standard of computed tomography (CT) in the canine.DesignThis was a prospective study.PopulationTwenty-five, client-owned dogs scheduled for CT as part of a diagnostic work-up for the management of their primary disease process were included.Materials and MethodsSpecific appendicular (cubital flexors and extensors, coxofemoral flexors and extensors) and axial (temporalis, supraspinatus, infraspinatus, lumbar epaxials) muscle groups were selected for quantitative measure based on CT planning and patient position. Prior to CT scan, the skin over the muscle sites was shaved and marked with a permanent marker. Patient body position was determined based on the patient’s CT plan; positioning was consistent between CT and US imaging. To ensure identical imaging position for both CT and US measurements, radio-opaque fiducial markers were placed directly over the skin marks once the dog was positioned. Quantitative measurements (cm) for both lean muscle mass (LMM) and subcutaneous adipose (SQA) were recorded. Statistical comparisons between CT and US values were done separately for each site and type.ResultsMuscle groups and associated SQA measured by US and CT were not statistically different based on an adjusted p-value using Bonferroni’s correction (p < 0.0031). In addition, all LMM and SQA sites had good reliability and agreement (Cronbach’s α = 0.8 − 1.0) between the two metrics, excluding the coxofemoral extensor muscle group (Cronbach’s α = 0.73232). Linear regression analysis of muscle measures indicated close agreement (slope range 0.93–1.09) and minimal bias of variation (intercept range 0.05–0.11) between CT versus US modalities, with the exception of the coxofemoral extensor muscle. Similarly, SQA CT and US measures indicated close agreement with the slope range of 0.88–1.02 and minimal bias of variation with an intercept range of 0.021–0.098, excluding the cubital flexor and extensor groups. Additionally, the R20.8289 for SQA.ConclusionsUltrasound imaging of selected appendicular and axial muscle groups in dogs can provide comparable assessment of muscle thickness to the current gold standard, CT. In consideration of both statistical reliability to CT and cage-side accessibility, the temporalis, supraspinatus, infraspinatus, and lumbar epaxial LMM sites are considered the most useful targets for US LMM assessment in the canine. Our findings support the potential utility of US as a clinical tool in veterinary medicine to assess LMM status in patients. Additional studies are indicated to develop standardized protocols of its use in a cage-side setting and to elucidate the benefit of this modality, in conjunction with nutritional interventions, to manage body LLM stores in compromised patients.
【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202307100014392ZK.pdf 3258KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次