Stability of important antibodies for kidney disease: pre-analytic methodological considerations
article
Qiuxia Han1  Songyan Li3  Bo Fu1  Dongwei Liu2  Maoqing Wu4  Xiaoli Yang1  Guangyan Cai1  Zhangsuo Liu2  Xiangmei Chen1  Hanyu Zhu1 
[1] Department of Nephrology, Chinese PLA General Hospital, Chinese PLA Institute of Nephrology, State Key Laboratory of Kidney Diseases, National Clinical Research Center for Kidney Diseases, Beijing Key Laboratory of Kidney Disease;Department of Nephrology of Zhenghou University, The First Affiliated Hospital of Zhengzhou University, Research Institute of Nephrology of Zhengzhou University, Key Laboratory of Precision Diagnosis and Treatment for Chronic Kidney Disease in Henan Province;Department of General Surgery, Chinese PLA General Hospital;Center for Translational Science, Children’s National Medical Center
关键词: anti-PLA2R antibodies;    anti-GBM antibodies;    anti-MPO antibodies;    anti-PR3 antibodies;    Storage;    Stability;   
DOI  :  10.7717/peerj.5178
学科分类:社会科学、人文和艺术(综合)
来源: Inra
PDF
【 摘 要 】

Background The importance of circulating antibodies as biomarkers of kidney disease has recently been recognized. However, no study has systematically described the methodology of sample preparation and storage regarding antibodies as biomarkers of kidney disease. It remains unknown whether repetitive freeze-thaw cycles, physical disturbances, storage at different temperatures or for different periods of time, or haemolytic or turbid serum samples affect antibody measurements. The aim of this study was to investigate the stabilities of antibodies associated with kidney disease in serum samples under various relevant clinical and research conditions. Methods We stored serum samples in the following different conditions: repetitive freeze-thaw cycles (1, 6 or 12 times), long-term storage (7 or 12 months at −80 °C), physical disturbance (1 or 8 h), and storage at 4 °C (1, 3 or 6 weeks) and room temperature (1 or 7 days). The stabilities of the anti-phospholipase A2 receptor (anti-PLA2R), anti-glomerular basement membrane, anti-myeloperoxidase and anti-proteinase 3 antibodies were evaluated with enzyme-linked immunosorbent assays (ELISA). Results We found that repetitive freeze-thaw cycles did not have a significant effect on the stabilities of the abovementioned antibodies in clear serum samples. The ELISA readings of haemolytic and turbid serum samples tended to increase and decrease, respectively. Neither long-term storage at −80 °C nor physical disturbance had a significant effect on anti-PLA2R antibody stability in sealed serum samples. The concentrations of most of these antibodies increased in unsealed serum samples that were stored at 4 °C for more than 6 weeks or at room temperature for more than 7 days. Discussion Our findings revealed that the abovementioned circulating antibodies that are used as biomarkers for kidney disease had stable physicochemical properties, structures and immunoreactivities such that they were not influenced by repetitive freeze-thaw cycles, physical disturbances or long-term storage at −80 °C. However, the ELISA readings tended to change for haemolytic, turbid and unsealed serum samples.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202307100012162ZK.pdf 1267KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:0次