期刊论文详细信息
PeerJ
On local scouring downstream small water structures
article
Marta Kiraga1  Zbigniew Popek2 
[1] Department of Hydrotechnics, Technology and Management, Institute of Civil Engineering, Warsaw University of Life Sciences WULS-SGGW;Department of Water Engineering and Applied Geology, Institute of Environmental Engineering, Warsaw University of Life Sciences WULS-SGGW
关键词: Hydraulic engineering;    Water structures;    River engineering;    Rivers;    Sediment transport;    Erosion;    Water construction;    Water;    Local scouring;    Hydrodynamics;   
DOI  :  10.7717/peerj.10282
学科分类:社会科学、人文和艺术(综合)
来源: Inra
PDF
【 摘 要 】

BackgroundIn order to regulate water flow, hydraulic structures such as weirs or checks, frequently equipped with gates, are used. Water can flow below or over the gate or, simultaneously, over and below the gate. Both diversifications of hydraulic gradient, being an effect of damming up a river by the structure and shear stresses at the bed, which exceeds the critical shear stress value, invoke the local scouring downstream the structure. This phenomenon has been studied in laboratory and field conditions for many years, however Researchers do not agree on the parameters that affect the size of the local scour and the intensity of its formation. There are no universal methods for estimating its magnitude However, solutions are sought in the form of calculation formulas typical for the method of flow through the structure, taking into account the parameters that characterize a given structure. These formulas are based on factors that affect the size of the local scours, that is, their dimensions and location. Examples of such formulas are those contained in this article: Franke (1960), Straube (1963), Tarajmovič (1966), Rossinski & Kuzmin (1969) equations. The need to study this phenomenon results from the prevalence of hydrotechnical structures equipped with gates (from small gated checks to large weirs) and from potential damage that may be associated with excessive development of local erosion downstream, including washing of foundations and, consequently, loss of stability of the structure.MethodsThis study verifies empirical formulas applied to estimate the geometry parameters of a scour hole on a laboratory model of a structure where water is conducted downstream the gate with bottom reinforcements of various roughness. A specially designed remote-controlled measuring device, equipped with laser scanner, was applied to determine the shape of the sandy bottom. Then the formula optimization is conducted, using Monte Carlo sampling method, followed by verification of field conditions.ResultsThe suitability of a specially designed device, equipped with laser scanner for measuring the bottom shape in laboratory conditions was demonstrated. Simple formula describing local scour geometry in laboratory conditions was derived basing on the Straube formula. The optimized formula was verified in field conditions giving very good comparative results. Therefore, it can be applied in engineering and designing practices.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202307100007199ZK.pdf 3389KB PDF download
  文献评价指标  