期刊论文详细信息
Journal of Applied Hematology
Evaluation of sensitivity and specificity of high fluorescence lymphocyte count percentage of sysmex XN analyzer in diagnosis of dengue
article
Aparna Ningombam1  Shreyam Acharya1  Abhirup Sarkar1  Kundan Kumar1  Megha Brijwal2  Srimantinee Routray1  Janya Sachdev2  Deepankar Srigyan2  Aashish Choudhary2  Arulselvi Subramanian1  Lalit Dar2 
[1] Department of Laboratory Medicine, All India Institute of Medical Sciences;Department of Microbiology, All India Institute of Medical Sciences
关键词: Dengue;    high fluorescence lymphocyte cell;    platelet;    reactive lymphocyte;    Sysmex;   
DOI  :  10.4103/joah.joah_204_20
学科分类:社会科学、人文和艺术(综合)
来源: Medknow
PDF
【 摘 要 】

BACKGROUND: The Sysmex XN-series hematology analyzers provide newer parameters including high fluorescence lymphocyte cell percentage (HFLC%) which correlates with the presence of atypical lymphocytes in peripheral blood. We aimed to analyze the sensitivity and specificity of HFLC% as a diagnostic tool and its association with serological status in diagnosed dengue patients and thereby establish a cutoff of HFLC% based on serology. Besides, we also wish to correlate HFLC% with thrombocytopenia in these patients. MATERIALS AND METHODS: A total of 1500 serum samples were subjected to serological evaluation for dengue. After excluding hematological malignancies and autoimmune disorders, the same day complete blood count parameters including HFLC% and platelet counts were collected retrospectively for 292 serologically positive dengue cases and 76 seronegative controls. RESULTS: Our result shows that in nonstructural 1 antigen-positive cases, a cutoff of >5.2% HFLC can have a sensitivity of 79.5% and specificity of 98.6%. We found a different cut off of HFLC% >3.2% (sensitivity 83.4%, specificity 98.6%) for the cases with only immunoglobulin M positivity and a cut off of HFLC% >2.6% (sensitivity 86.1%, specificity 96%) in the dual positive cases (immunoglobulin M with nonstructural 1 antigen). Besides, high HFLC% also shows a strong correlation with platelet count with a Spearman correlation coefficient of −0.6. CONCLUSIONS: The result of our study shows that a specific cutoff of HFLC% can not only help us to suspect dengue fever but also predict the risk of thrombocytopenia in already diagnosed dengue patients. The sensitivity and specificity of HFLC% varied with the serological status of the patients which depend on the days of fever on presentation.

【 授权许可】

CC BY-NC-SA   

【 预 览 】
附件列表
Files Size Format View
RO202307100000749ZK.pdf 1543KB PDF download
  文献评价指标  