期刊论文详细信息
Balkan Journal of Dental Medicine
Comparative evaluation of resistance to cyclic fatigue of three rotary endodontic Ni-Ti instruments
article
Intzes Lampros1  Tzima Zoi-Despoina1  Gogos Christos1 
[1] Aristotle University of Thessaloniki, School of Dentistry, Department of Endodontology
关键词: Cyclic Fatigue;    Nickel-Titanium Rotary Instruments;    K3xf;    Hyflex Cm;    X7 Edgefile;   
DOI  :  10.2478/bjdm-2019-0007
学科分类:社会科学、人文和艺术(综合)
来源: Walter de Gruyter GmbH
PDF
【 摘 要 】

Background/Aim: The present study examined the resistance to cyclic fatigue of three different rotary Ni-Ti instruments: K3XF (Kerr, Orange, CA), HyFlex CM (Coltene/Whaledent, Altstätten, Switzerland) and X7 EdgeFile (EdgeEndo, Albuquerque, New Mexico). Material and Methods: Thirty instruments (n=30) of each type were used with tip size 25 and 0.04 taper. All instruments were constrained to 600 of curvature with a radius of 5 mm by the use of two grooved stainless steel rods and rotated at a speed of 300 rpm and 3.0 Ncm of torque. The time until separation was recorded for each of the instruments and the number of cycles to fracture (NCF) was calculated. Statistical analysis was performed using R Programming language. Results: The X7 EdgeFile instrument showed significantly greater resistance to cyclic fatigue when compared to the HyFlex CM and the K3XF with mean NCF for each instrument 1046 ± 311, 707 ± 219 and 360 ± 96 respectively. HyFlex CM performed significantly better than K3XF. Conclusions: The X7 EdgeFile Ni-Ti file appears to be significantly more resistant to fracture, due to flexural fatigue, than the HyFlex CM and the K3XF.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202307090004145ZK.pdf 399KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:1次