| Balkan Journal of Dental Medicine | |
| Examination of scanner precision by analysing orthodontic parameters | |
| article | |
| Majstorović Nemanja1  Čerče Luka2  Kramar Davorin2  Soković Mirko2  Glišić Branislav1  Majstorović Vidosav1  Živković Srđan3  | |
| [1] Univerzitet u Beogradu;University of Ljubljana, Faculty of Mechanical Engineering;Vojnotehnički institut - VTI | |
| 关键词: scanning; 3D modelling; orthodontics; precision; | |
| DOI : 10.1515/bjdm-2017-0005 | |
| 学科分类:社会科学、人文和艺术(综合) | |
| 来源: Walter de Gruyter GmbH | |
PDF
|
|
【 摘 要 】
Background: 3D modelling in orthodontics is becoming an increasingly widespread technique in practice. One of the significant questions already being asked is related to determining the precision of the scanner used for generating surfaces on a 3D model of the jaw. Materials and methods: This research was conducted by generating a set of identical 3D models on Atos optical 3D scanner and Lazak Scan laboratory scanner, which precision was established by measuring a set of orthodontic parameters (54 overall) in all three orthodontic planes. In this manner we explored their precision in space, since they are used for generating spatial models - 3D jaws. Results: There were significant differences between parameters scanned with Atos and Lazak Scan. The smallest difference was 0.017 mm, and the biggest 1.109 mm. Conclusion: This research reveals that both scanners (Atos and Lazak Scan), which belong to general purpose scanners, based on precision parameters can be used in orthodontics. Early analyses indicate that the reference scanner in terms of precision is Atos.
【 授权许可】
CC BY
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202307090004083ZK.pdf | 1183KB |
PDF