期刊论文详细信息
Journal of Lasers in Medical Sciences
Physicochemical Changes of Contaminated Titanium Discs Treated With Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) Laser Irradiation or AirFlow Abrasion: An In Vitro Study
article
Reza Amid1  Mahdi Kadkhodazadeh2  Seyed Massoud Mojahedi2  Maedeh Gilvari Sarshari3  Zeinab Zamani4 
[1] Department of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences;Department of Laser, School of Dentistry, Shahid Beheshti University of Medical Sciences;Research Institute of Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences;Post graduate student, Research Institute of Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences
关键词: Peri-Implantitis;    Lasers;    Decontamination;    Wettability;    SEM;    Energy Dispersive X-ray Spectroscopy;   
DOI  :  10.34172/jlms.2021.67
学科分类:基础医学
来源: Shahid Beheshti University of Medical Sciences
PDF
【 摘 要 】

Introduction: Peri-implantitis is a common complication of dental implant treatment. A cause-and effect relationship has been previously documented between microbial plaque and peri-implantitis and implant failure. A difference has been reported in the disinfection efficacy of erbium laser irradiation and air-flow abrasion for contaminated titanium surfaces. Also, the surface changes caused by lasers and air-flow abrasion have not been well studied. Thus, the purpose of this study was to compare the surface changes of contaminated titanium discs following decontamination by erbium-doped yttrium aluminum garnet (Er: YAG) laser irradiation and air-flow abrasion.Methods: Twenty-eight intact, sandblasted, and acid-etched (SLA) titanium discs were used. Twentyfour titanium discs were contaminated with Escherichia coli. Then, they were decontaminated by using Er: YAG laser irradiation and air-flow abrasion. Four discs remained intact. The mean and standard deviation of the contact angle and the weight percentage of aluminum, titanium, oxygen, carbon, phosphorus, and calcium were measured. Qualitative changes in surface topography of titanium discs were assessed by scanning electron microscopy (SEM).Results: The mean weight percentage of carbon in the air-flow abrasion group (4.98%) experienced a significant reduction compared with the contaminated (positive control) group (P=0.035). The contact angles were 46.54° and 38.67° in the laser and air-flow abrasion groups respectively, which were significantly lower than the value in the positive control group (75.15°) (P ≤0.001). SEM micrographs showed no significant change in the surface area in either technique.Conclusion: Air-flow abrasion was more successful in improving the surface characteristics of titanium discs with no alteration in surface topography or elements, compared with Er: YAG laser irradiation. Further studies regarding the safety of the Er: YAG laser for the decontamination of titanium surfaces are recommended.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202307060002803ZK.pdf 2016KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:2次