| Static Load Test Study on Long-span Continuous Rigid Frame Bridge with V-shaped Pier | |
| article | |
| Fei Zhang1  Yan Wang1  | |
| [1] College of Engineering, Fujian Jiangxia University | |
| DOI : 10.1088/1755-1315/295/4/042062 | |
| 学科分类:材料科学(综合) | |
| 来源: Institute Of Physics Publishing | |
PDF
|
|
【 摘 要 】
Taking the main bridge of the shuidong bridge in Youxi country of Fujian province as background, this paper develops the static characteristic analysis and static load test study on long-span prestressed continuous rigid frame bridge with V-shaped pier. By the analysis and comparison between the measured data and FEA results, it evaluates the working condition of the bridge. The results show: Firstly,each evaluation indicator tested meets the requirements of "Test methods for large-span concrete bridges" Secondly, the strain efficacy coefficient of measured points in top plate of each control section is within 0.65∼0.74, and that of the measured points in bottom plate is within 0.64∼0.73, the residual strain of the measured points is less, therefore, the safety stock of the bridge is sufficient, and it is on the flexible working condition basically; Finally, the measured value and the theoretical value of deflection curves along the longitudinal bridge is compatible, the efficacy coefficient of vertical deformation is within 0.55∼0.85, and the severity of the practical structure is more.