期刊论文详细信息
Journal of Thoracic Disease
Navigational bronchoscopy specimens and PD-L1 expression: a retrospective study
article
Hussein Asad1  Timothy Saettele2  Ossama Tawfik3  Philip Jones4  Matthew Aboudara2 
[1] Department of Pulmonary and Critical Care, University of Missouri-Kansas City School of Medicine;Division of Pulmonary and Critical Care, Saint Luke’s Health System, Frank and Evangeline Thompson Thoracic Center;Department of Pathology, Saint Luke’s Health System;Deparment of Cardiovascular Research, Saint Luke’s Health System
关键词: Bronchoscopy;    lung neoplasms;    non-small cell lung cancer (NSCLC);    biopsy;   
DOI  :  10.21037/jtd-21-1454
学科分类:呼吸医学
来源: Pioneer Bioscience Publishing Company
PDF
【 摘 要 】

Background: Additional data regarding the ability of navigational bronchoscopy (NB) to provide sufficient material for programmed death-ligand 1 (PD-L1) expression is needed. We performed a retrospective study of NB cases at our institution to determine performance of NB in providing adequate samples for PD-L1. Methods: We conducted a retrospective review of all consecutive NB procedures performed at our institution from January 1, 2018 to August 4, 2020 that involved biopsies of a lung nodule/mass with a diagnosis of non-small cell lung cancer (NSCLC). The primary outcome was adequacy of material for PD-L1 testing. All procedural, demographic, and diagnostic data were collected. The association of factors with PD-L1 adequacy was evaluated with rate ratios (RR) using modified Poisson regression models with robust standard errors. Results: A total of 102 NB procedures with a diagnosis of NSCLC were performed over a 2-year period. The mean [standard deviation (SD)] nodule size was 25.0 [interquartile range (IQR), 18.0–32.0] mm and 57.8% (59/102) had a bronchus sign; 73% (68/93, 9 missing data) of samples were adequate for PD-L1 testing. Radial endobronchial ultrasound (REBUS) was utilized in 99% (101/102) of biopsies; a concentric or eccentric view was observed in 78.2% (79/101) and 16.8% (17/101), respectively. Transbronchial biopsy (TBBX) was performed in 92.2% (94/102). Only 4% (4/102) of cases required additional biopsies with either computed tomography (CT) guided transthoracic or surgical biopsies due to insufficient bronchoscopy tissue. No factors were predictive of PD-L1 adequacy in regression models. Conclusions: NB demonstrated good performance in obtaining adequate samples for PD-L1 testing. Only 4% of patients required additional procedures for more tissue when clinically indicated. However, additional study is needed to validate these results against surgical resection specimens.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO202307020004329ZK.pdf 275KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:0次