期刊论文详细信息
Urban Science
Identification of Critical Locations for Improvement of Air Quality Developing a Prioritized Clean Air Assessment Tool (PCAT)
article
Kanishtha Dubey1  Shubha Verma1  Sauvik Santra1  Mukul Kumar2 
[1] Department of Civil Engineering, Indian Institute of Technology Kharagpur;Advance Technology Development Centre, Indian Institute of Technology Kharagpur
关键词: air quality index;    air quality assessment;    mitigation;    air pollution;    India;    permissible limit;   
DOI  :  10.3390/urbansci7030075
学科分类:社会科学、人文和艺术(综合)
来源: mdpi
PDF
【 摘 要 】

100). However, it was found that NAQI values over the locations are driven by the undifferentiated mass concentration of particulate matter (PM, both PM10 and PM2.5) than other criteria pollutants. The PM2.5 and PM10 concentration during the winter violated the National Ambient Air Quality Standards (NAAQS) of India by two to five times at six urban locations, with the mean daily PM2.5 concentration averaged over the month; the the largest being at Patna (353 µg m−3) during the winter and lowest at Bengaluru (27 µg m−3) during the summer. The analysis of chemical species, in general, indicated NO2 (SO2, CO) as having a 25% to 70% (16% to 50%, 16% to 85%) increase in concentration from the summer to winter, which is adequately reflected in higher fuzzy scores during the winter. Thus, to provide a realistic approach to air quality management, the present study focuses on identifying priority-based locations requiring immediate mitigation measures by developing a Prioritized Clean Air Assessment Tool (PCAT). The tool utilizes a fuzzy-based algorithm to incorporate the cumulative effect of all six criteria pollutants, taking into consideration the severity of their expected health implications. Using PCAT, Delhi and Varanasi cities are identified for prioritized mitigation considering the NAAQS of India, unlike all cities (except Bengaluru) during the winter and nine out of fourteen cities during the summer, considering the NAQI. Using more stringent WHO guideline values in PCAT, six cities out of fourteen were identified requiring immediate mitigation during the winter and summer months; locations such as Solapur and Patna are identified to need season-specific mitigation measures during the summer and winter, respectively. The tool is simplistic, user-friendly, and quickly evaluates multiple locations simultaneously to provide priority sites.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202307010002285ZK.pdf 835KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:2次