Background-We reviewed the literature pertaining to the cost-effectiveness of implantable cardioverter-defibrillator (ICD) therapy in the management of ventricular fibrillation and tachycardia. Discussed are the methodology, advantages, and limitations of economic-outcomes analyses as related to ICD therapy; the impact of new technology and physician practice patterns; and methodological recommendations for future studies. Methods and Results-Articles published between 1990 and 1997 were screened for cost-effectiveness analyses of ICD versus antiarrhythmic drug therapy. Randomized clinical trials, prospective and retrospective studies, and economic models were included. These studies report incremental cost-effectiveness ratios ranging from cost savings of $13 975 per life-year saved (LYS) to an incremental cost of $114 917 per LYS for ICD therapy. Differences were due to study type, cost-reporting methodology, ICD technology used, and length of follow-up. Assuming current technology and physician practice patterns, we find that ICD total therapy costs may break even in 1 to 3 years. Conclusions-Recent literature suggests that ICDs are a cost-effective therapy for management of life-threatening ventricular tachyarrhythmias. The advent of new technology and patient management practices should further improve the cost-effectiveness of ICD therapy. Future studies of ICD cost-effectiveness should address the implications of truncated follow-up periods and quality of life.