| The use of dedicated long-axis views focused on the left atrium improves the accuracy of left atrial volumes and emptying fraction measured by cardiovascular magnetic resonance | |
| Research | |
| Stefano Figliozzi1  Camilla Torlasco2  Denisa Muraru3  Luigi P. Badano3  Gianfranco Parati3  Diana R. Florescu4  Lara Tondi5  Antonia Camporeale5  Massimo Lombardi5  Silvia Pica5  Giandomenico Disabato6  | |
| [1] Clinical Echocardiography Diagnostic Service, Cardio Center, Humanitas Research Hospital IRCCS, Rozzano, Milan, Italy;Department of Cardiology, Istituto Auxologico Italiano IRCCS, Milan, Italy;Department of Cardiology, Istituto Auxologico Italiano IRCCS, Milan, Italy;Department of Medicine and Surgery, University Milano-Bicocca, Milan, Italy;Department of Medicine and Surgery, University Milano-Bicocca, Milan, Italy;Department of Cardiology, University of Medicine and Pharmacy of Craiova, Craiova, Romania;Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy;Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy;University of Pavia, Pavia, Italy; | |
| 关键词: Left atrial volume; Left atrial emptying fraction; Left atrial strain; Cardiac magnetic resonance; Accuracy; | |
| DOI : 10.1186/s12968-022-00905-w | |
| received in 2022-05-23, accepted in 2022-11-29, 发布年份 2022 | |
| 来源: Springer | |
PDF
|
|
【 摘 要 】
BackgroundThe use of apical views focused on the left atrium (LA) has improved the accuracy of LA volume evaluation by two-dimensional (2D) echocardiography. However, routine cardiovascular magnetic resonance (CMR) evaluation of LA volumes still uses standard 2- and 4-chamber cine images focused on the left ventricle (LV). To investigate the potential of LA-focused CMR cine images, we compared LA maximuml (LAVmax) and minimum (LAVmin) volumes, and emptying fraction (LAEF), calculated on both standard and LA-focused long-axis cine images, with LA volumes and LAEF obtained by short-axis cine stacks covering the LA. LA strain was also calculated and compared between standard and LA-focused images.MethodsLA volumes and LAEF were obtained from 108 consecutive patients by applying the biplane area-length algorithm to both standard and LA-focused 2- and 4-chamber cine images. Manual segmentation of a short-axis cine stack covering the LA was used as the reference method. In addition, LA strain reservoir (εs), conduit (εe) and booster pump (εa) were calculated using CMR feature-tracking.ResultsCompared to the reference method, the standard approach significantly underestimated LA volumes (LAVmax: bias − 13 ml; LOA = + 11, − 37 ml; LAVmax i: bias − 7 ml/m2; LOA = + 7, − 21 ml/m2; LAVmin; bias − 10 ml, LOA: + 9, − 28 ml; LAVmin i: bias − 5 ml/m2, LOA: + 5, − 16 ml/m2), and overestimated LA-EF (bias 5%, LOA: + 23, − 14%). Conversely, LA volumes (LAVmax: bias 0 ml; LOA: + 10, − 10 ml; LAVmax i: bias 0 ml/m2; LOA: + 5, − 6 ml/m2; LAVmin: bias − 2 ml; LOA: + 7, − 10 ml; LAVmin i: bias − 1 ml/m2; LOA: + 3, − 5 ml/m2) and LAEF (bias 2%, LOA: + 11, − 7%) by LA-focused cine images were similar to those measured using the reference method. LA volumes by LA-focused images were obtained faster than using the reference method (1.2 vs 4.5 min, p < 0.001). LA strain (εs: bias 7%, LOA = 25, − 11%; εe: bias 4%, LOA = 15, − 8%; εa: bias 3%, LOA = 14, − 8%) was significantly higher in standard vs. LA-focused images (p < 0.001).ConclusionLA volumes and LAEF measured using dedicated LA-focused long-axis cine images are more accurate than using standard LV-focused cine images. Moreover, LA strain is significantly lower in LA-focused vs. standard images.
【 授权许可】
CC BY
© The Author(s) 2023
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202305159510710ZK.pdf | 2350KB | ||
| Fig. 6 | 1714KB | Image | |
| 13690_2023_1046_Article_IEq4.gif | 1KB | Image | |
| Fig. 4 | 1470KB | Image | |
| Fig. 12 | 1246KB | Image | |
| MediaObjects/13227_2022_206_MOESM1_ESM.docx | 567KB | Other | |
| Fig. 13 | 1590KB | Image | |
| Fig. 4 | 899KB | Image | |
| Fig. 12 | 108KB | Image | |
| 40517_2023_248_Article_IEq5.gif | 1KB | Image |
【 图 表 】
40517_2023_248_Article_IEq5.gif
Fig. 12
Fig. 4
Fig. 13
Fig. 12
Fig. 4
13690_2023_1046_Article_IEq4.gif
Fig. 6
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]
- [36]
- [37]
- [38]
- [39]
PDF