Journal of Cardiovascular Magnetic Resonance
The use of dedicated long-axis views focused on the left atrium improves the accuracy of left atrial volumes and emptying fraction measured by cardiovascular magnetic resonance
Research
Stefano Figliozzi1  Camilla Torlasco2  Denisa Muraru3  Luigi P. Badano3  Gianfranco Parati3  Diana R. Florescu4  Lara Tondi5  Antonia Camporeale5  Massimo Lombardi5  Silvia Pica5  Giandomenico Disabato6 
[1] Clinical Echocardiography Diagnostic Service, Cardio Center, Humanitas Research Hospital IRCCS, Rozzano, Milan, Italy;Department of Cardiology, Istituto Auxologico Italiano IRCCS, Milan, Italy;Department of Cardiology, Istituto Auxologico Italiano IRCCS, Milan, Italy;Department of Medicine and Surgery, University Milano-Bicocca, Milan, Italy;Department of Medicine and Surgery, University Milano-Bicocca, Milan, Italy;Department of Cardiology, University of Medicine and Pharmacy of Craiova, Craiova, Romania;Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy;Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy;University of Pavia, Pavia, Italy;
关键词: Left atrial volume;    Left atrial emptying fraction;    Left atrial strain;    Cardiac magnetic resonance;    Accuracy;   
DOI  :  10.1186/s12968-022-00905-w
 received in 2022-05-23, accepted in 2022-11-29,  发布年份 2022
来源: Springer
PDF
【 摘 要 】

BackgroundThe use of apical views focused on the left atrium (LA) has improved the accuracy of LA volume evaluation by two-dimensional (2D) echocardiography. However, routine cardiovascular magnetic resonance (CMR) evaluation of LA volumes still uses standard 2- and 4-chamber cine images focused on the left ventricle (LV). To investigate the potential of LA-focused CMR cine images, we compared LA maximuml (LAVmax) and minimum (LAVmin) volumes, and emptying fraction (LAEF), calculated on both standard and LA-focused long-axis cine images, with LA volumes and LAEF obtained by short-axis cine stacks covering the LA. LA strain was also calculated and compared between standard and LA-focused images.MethodsLA volumes and LAEF were obtained from 108 consecutive patients by applying the biplane area-length algorithm to both standard and LA-focused 2- and 4-chamber cine images. Manual segmentation of a short-axis cine stack covering the LA was used as the reference method. In addition, LA strain reservoir (εs), conduit (εe) and booster pump (εa) were calculated using CMR feature-tracking.ResultsCompared to the reference method, the standard approach significantly underestimated LA volumes (LAVmax: bias − 13 ml; LOA =  + 11, − 37 ml; LAVmax i: bias − 7 ml/m2; LOA =  + 7, − 21 ml/m2; LAVmin; bias − 10 ml, LOA: + 9, − 28 ml; LAVmin i: bias − 5 ml/m2, LOA: + 5, − 16 ml/m2), and overestimated LA-EF (bias 5%, LOA: + 23, − 14%). Conversely, LA volumes (LAVmax: bias 0 ml; LOA: + 10, − 10 ml; LAVmax i: bias 0 ml/m2; LOA: + 5, − 6 ml/m2; LAVmin: bias − 2 ml; LOA: + 7, − 10 ml; LAVmin i: bias − 1 ml/m2; LOA: + 3, − 5 ml/m2) and LAEF (bias 2%, LOA: + 11, − 7%) by LA-focused cine images were similar to those measured using the reference method. LA volumes by LA-focused images were obtained faster than using the reference method (1.2 vs 4.5 min, p < 0.001). LA strain (εs: bias 7%, LOA = 25, − 11%; εe: bias 4%, LOA = 15, − 8%; εa: bias 3%, LOA = 14, − 8%) was significantly higher in standard vs. LA-focused images (p < 0.001).ConclusionLA volumes and LAEF measured using dedicated LA-focused long-axis cine images are more accurate than using standard LV-focused cine images. Moreover, LA strain is significantly lower in LA-focused vs. standard images.

【 授权许可】

CC BY   
© The Author(s) 2023

【 预 览 】
附件列表
Files Size Format View
RO202305159510710ZK.pdf 2350KB PDF download
Fig. 6 1714KB Image download
13690_2023_1046_Article_IEq4.gif 1KB Image download
Fig. 4 1470KB Image download
Fig. 12 1246KB Image download
MediaObjects/13227_2022_206_MOESM1_ESM.docx 567KB Other download
Fig. 13 1590KB Image download
Fig. 4 899KB Image download
Fig. 12 108KB Image download
40517_2023_248_Article_IEq5.gif 1KB Image download
【 图 表 】

40517_2023_248_Article_IEq5.gif

Fig. 12

Fig. 4

Fig. 13

Fig. 12

Fig. 4

13690_2023_1046_Article_IEq4.gif

Fig. 6

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  文献评价指标  
  下载次数:16次 浏览次数:0次