期刊论文详细信息
BMC Oral Health
Effect of filament types and loops number on the force degradation of elastomeric chains used for orthodontic treatment: an in-vitro study
Research
Bowen Zheng1  Yang Zhao1  Yi Liu1  Zhiyuan Li1  Majedh Abdo Ali Al-Somairi2 
[1] Department of Orthodontics, School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, 110002, Shenyang, China;Department of Orthodontics, School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, 110002, Shenyang, China;Department of Orthodontics and Dentofacial Orthopedics, Faculty of Dentistry, Ibb University, Ibb, Republic of Yemen;
关键词: Elastomeric chain;    Force degradation;    Thermal cycle;   
DOI  :  10.1186/s12903-023-02812-7
 received in 2022-09-18, accepted in 2023-02-13,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundIn orthodontic treatment, closing spaces, specifically the extraction and scattered spaces of the anterior teeth, requires some auxiliary bias, such as an elastomeric chain. Many factors affect the mechanical properties of elastic chains. In this study, we investigated the relationship of the filament type, the number of loops, and the force degradation of elastomeric chains under thermal cycling conditions.MethodsThe orthogonal design included three filament types (i.e., close, medium, and long). Four, five, and six loops of each elastomeric chain were stretched to have an initial force of 250 g in an artificial saliva environment at 37 °C and thermocycling between 5 and 55 °C three times a day. The remaining force of the elastomeric chains was recorded at different time points (4 h, 24 h, 7 days, 14 days, 21 days, and 28 days), and the percentage of the remaining force was calculated.ResultsThe force decreased significantly in the initial 4 h and degraded mostly within the first 24 h. In addition, the percentage of force degradation increased slightly between 1 and 28 days.ConclusionsUnder the same initial force, the longer the connecting body is, the fewer the number of loops and the greater the force degradation of the elastomeric chain are.

【 授权许可】

CC BY   
© The Author(s) 2023

【 预 览 】
附件列表
Files Size Format View
RO202305155765616ZK.pdf 901KB PDF download
40517_2023_248_Article_IEq10.gif 1KB Image download
40517_2023_248_Article_IEq23.gif 1KB Image download
40517_2023_248_Article_IEq35.gif 1KB Image download
Fig. 1 538KB Image download
Fig. 1 1688KB Image download
Fig. 5 493KB Image download
【 图 表 】

Fig. 5

Fig. 1

Fig. 1

40517_2023_248_Article_IEq35.gif

40517_2023_248_Article_IEq23.gif

40517_2023_248_Article_IEq10.gif

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  文献评价指标  
  下载次数:21次 浏览次数:4次