International Journal of Implant Dentistry | |
Comparison of the accuracy of immediate implant placement using static and dynamic computer-assisted implant system in the esthetic zone of the maxilla: a prospective study | |
Research | |
Zhenya Su1  Xingmei Yang1  Yuzhang Feng1  Anchun Mo1  | |
[1] State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, No.14, 3rd Section, Renmin Nan Road, Chengdu, Sichuan, People’s Republic of China; | |
关键词: Accuracy; Computer-assisted surgery; Dental implant; Immediate implant placement; Dynamic navigation; Static template; | |
DOI : 10.1186/s40729-022-00464-w | |
received in 2022-11-02, accepted in 2022-12-07, 发布年份 2022 | |
来源: Springer | |
【 摘 要 】
PurposeThis study aimed to compare the accuracy of fully guided between dynamic and static computer-assisted implant surgery (CAIS) systems for immediate implant placement in the esthetic zone.MethodsA total of 40 qualified patients requiring immediate implant placement in the esthetic zone were randomly and equally assigned to either static CAIS group (n = 20) or dynamic CAIS groups (n = 20). Global deviations at entry, apex, and angular deviation between placed and planned implant position were measured and compared as primary outcomes. Secondary outcomes were the deviation of implant placement at mesial–distal, labial–palatal, and coronal–apical directions.ResultsFor the immediate implant placement, the mean global entry deviations in static and dynamic CAIS groups were 0.99 ± 0.63 mm and 1.06 ± 0.55 mm (p = 0.659), while the mean global apex deviations were 1.50 ± 0.75 mm and 1.18 ± 0.53 mm (p = 0.231), respectively. The angular deviation in the static and dynamic CAIS group was 3.07 ± 2.18 degrees and 3.23 ± 1.67 degrees (p = 0.547). No significant differences were observed for the accuracy parameters of immediate implant placement between static and dynamic CAIS systems, except the deviation of the implant at entry in the labial–palatal direction in the dynamic CAIS group was significantly more labial than of the static CAIS (p = 0.005).ConclusionsThis study demonstrated that clinically acceptable accuracy of immediate implant placement could be achieved using static and dynamic CAIS systems.Trial registration ChiCTR, ChiCTR2200056321. Registered 3 February 2022, http://www.chictr.org.cn/showproj.aspx?proj=151348
【 授权许可】
CC BY
© The Author(s) 2022
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202305067068546ZK.pdf | 1505KB | download | |
Fig. 6 | 530KB | Image | download |
13690_2022_1011_Article_IEq4.gif | 1KB | Image | download |
Fig. 3 | 401KB | Image | download |
Fig. 1 | 455KB | Image | download |
MediaObjects/12974_2022_2653_MOESM6_ESM.docx | 26KB | Other | download |
【 图 表 】
Fig. 1
Fig. 3
13690_2022_1011_Article_IEq4.gif
Fig. 6
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]