Quantitative Imaging in Medicine and Surgery
A novel standardized approach for the 3D evaluation of upper eyelid area and volume
article
Yongwei Guo1  Alexander C. Rokohl3  Wanlin Fan3  Rodothea Theodosiou3  Xueting Li3  Lixia Lou1  Tao Gao1  Ming Lin5  Ke Yao1  Ludwig M. Heindl3 
[1] Eye Center, Second Affiliated Hospital , Zhejiang University School of Medicine;Zhejiang Provincial Key Lab of Ophthalmology;Department of Ophthalmology, University of Cologne , Faculty of Medicine and University Hospital of Cologne;Center for Integrated Oncology;Department of Ophthalmology, Ninth People’s Hospital , Shanghai Jiao Tong University School of Medicine
关键词: Area;    volume;    eyelid;    three-dimensional (3D);    photogrammetry;   
DOI  :  10.21037/qims-22-589
学科分类:外科医学
来源: AME Publications
PDF
【 摘 要 】

Background: Three-dimensional (3D) surface imaging and morphometrics are becoming the preferred craniofacial surface imaging modality. However, as a unique advantage of 3D imaging, areal and volumetric measurements have been rarely conducted and validated for evaluating soft tissue change in the periocular region, especially the upper eyelids. Therefore, based on an existing periocular landmark identification strategy, we proposed a novel modified method to define a standardized upper eyelid region for areal and volumetric measurements and validate its reliability for future clinical application. Methods: Forty-four healthy adult volunteers were enrolled in this cross-sectional study. Three-dimensional facial images were taken with a 3D imaging system. Subsequently, the upper eyelid region selection and areal and volumetric measurements were conducted using a modified landmarks localization strategy to evaluate their intrarater, interrater, and intramethod reliability. Results: Areal measurement of the upper eyelid revealed highly reliable outcomes for intraclass correlation coefficient (ICC), mean absolute difference (MAD), relative error measurement (REM), technical error of measurement (TEM), and relative technical error of measurement (%TEM) of 0.982, 0.1620 cm2, 2.9%, 0.1510 cm2, and 2.7% for intrarater reliability, respectively; 0.969, 0.2076 cm2, 3.7%, 0.1930 cm2, and 3.5% for interrater reliability, respectively; and 0.917, 0.3636 cm2, 6.5%, 0.3354 cm2, and 6.0% for intramethod reliability, respectively. Unsatisfactory results were found for the volumetric measurement of the upper eyelid: the ICC, MAD, REM, TEM, and %TEM estimates for intrarater reliability were 0.992, 0.2299 mL, 10.3%, 0.2414 mL, and 10.8%, respectively; for interrater reliability, these values were 0.985, 0.2749 mL, 12.3%, 0.3253 mL, and 14.6%, respectively; and for intramethod reliability, these values were 0.433, 1.6716 mL, 77.9%, 2.0615 mL, and 96.1%, respectively. Conclusions: This is the first study to propose a standardized upper eyelid region selection strategy and simultaneously validate its reliability for 3D areal and volumetric measurements. This study confirmed the high-level reliability of areal measurement and poor reliability of volumetric measurement based on direct measurements using a single image, which may provide better results when this method is combined with the image overlapping and registration procedure. However, this is subject to further validation. Nonetheless, this method could provide quantitative areal and volumetric data on the upper eyelids and might have widespread application potential in the future.

【 授权许可】

All Rights reserved   

【 预 览 】
附件列表
Files Size Format View
RO202303290000717ZK.pdf 539KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:0次