期刊论文详细信息
Quantitative Imaging in Medicine and Surgery
Early results of ultra-low-dose CT-scan for extremity traumas in emergency room
article
Taki Eddine Addala1  Joël Greffier1  Aymeric Hamard1  Fehmi Snene1  Xavier Bobbia2  Sophie Bastide3  Asmaa Belaouni1  Hélène de Forges1  Ahmed Larbi1  Jean-Emmanuel de la Coussaye2  Jean-Paul Beregi1  Pierre-Géraud Claret2  Julien Frandon1 
[1] IMAGINE Research Unit 103 , Department of Medical Imaging, Nîmes University Hospital , Montpellier University;IMAGINE Research Unit 103 , Emergency Department, Nîmes University Hospital , Montpellier University;Department of Biostatistics, Epidemiology, Public Health and Innovation in Methodology
关键词: Radiation dose;    CT scan;    X-ray;    extremity traumatism;    emergency radiology;   
DOI  :  10.21037/qims-21-848
学科分类:外科医学
来源: AME Publications
PDF
【 摘 要 】

Background: Ultra-low dose computed tomography (ULD-CT) was shown to be a good alternative to digital radiographs in various locations. This study aimed to assess the diagnostic sensitivity and specificity of ULD-CT versus digital radiographs in patients consulting for extremity traumas in emergency room. Methods: Digital radiography and ULD-CT scan were performed in patients consulting at the emergency department (February–August 2018) for extremity traumas. Fracture detection was evaluated retrospectively by two blinded independent radiologists. Sensitivity and specificity were evaluated using best value comparator (BVC) and a Bayesian latent class model (LCM) approaches and clinical follow-up. Image quality, quality diagnostic and diagnostic confidence level were evaluated (Likert scale). The effective dose received was calculated. Results: Seventy-six consecutive patients (41 men, mean age: 35.2±13.2 years), with 31 wrists/hands and 45 ankles/feet traumas were managed by emergency physicians. According to clinical data, radiography had 3 false positive and 10 false negative examinations, and ULD-CT, 2 of each. Radiography and ULD-CT specificities were similar; sensitivities were lower for radiography, with BVC and Bayesian. With Bayesian, ULD-CT and radiography sensitivities were 90% (95% CI: 87–93%) and 76% (95% CI: 71–81%, P<0.0001) and specificities 96% (95% CI: 93–98%) and 93% (95% CI: 87–97%, P=0.84). The inter-observer agreement was higher for ULD-CT for all subjective indexes. The effective dose for ULD-CT and radiography was 0.84±0.14 and 0.58±0.27 µSv (P=0.002) for hand/wrist, and 1.50±0.32 and 1.44±0.78 µSv (P=NS) for foot/ankle. Conclusions: With an effective dose level close to radiography, ULD-CT showed better detection of extremities fractures in the emergency room and may allow treatment adaptation. Further studies need to be performed to assess impact of such examination in everyday practice. Trial Registration: ClinicalTrials.gov Identifier: NCT04832490.

【 授权许可】

All Rights reserved   

【 预 览 】
附件列表
Files Size Format View
RO202303290000465ZK.pdf 879KB PDF download
  文献评价指标  