期刊论文详细信息
Frontiers in Cardiovascular Medicine
Ventriculo-Arterial Coupling Is Associated With Oxygen Consumption and Tissue Perfusion in Acute Circulatory Failure
article
Stefan Andrei1  Maxime Nguyen1  Dan Longrois4  Bogdan A. Popescu2  Belaid Bouhemad1  Pierre-Grégoire Guinot1 
[1] Anaesthesiology and Critical Care Department, Dijon Bourgogne University Hospital;Department of Anaesthesia and Intensive Care, University of Medicine and Pharmacy “Carol Davila”;LNC UMR1231, University of Burgundy Franche Comte;Anaesthesiology and Critical Care Department, Bichat Claude Bernard Hospital and INSERM1148;Department of Cardiology, Emergency Institute for Cardiovascular Diseases “Prof. Dr. C. C. Iliescu”
关键词: ventricular-arterial coupling;    oxygen delivery;    oxygen consumption;    fluid therapy;    norepinephrine;    acute circulatory failure;   
DOI  :  10.3389/fcvm.2022.842554
学科分类:地球科学(综合)
来源: Frontiers
PDF
【 摘 要 】

Introduction The determination of ventriculo-arterial coupling is gaining an increasing role in cardiovascular and sport medicine. However, its relevance in critically ill patients is still under investigation. In this study we measured the association between ventriculo-arterial coupling and oxygen consumption (VO 2 ) response after hemodynamic interventions in cardiac surgery patients with acute circulatory instability. Material and Methods Sixty-one cardio-thoracic ICU patients (67 ± 12 years, 80% men) who received hemodynamic therapeutic interventions (fluid challenge or norepinephrine infusion) were included. Arterial pressure, cardiac output, heart rate, arterial (E A ), and ventricular elastances (E V ), total indexed peripheral resistances were assessed before and after hemodynamic interventions. VO 2 responsiveness was defined as VO 2 increase >15% following the hemodynamic intervention. Ventriculo-arterial coupling was assessed measuring the E A /E V ratio by echocardiography. The left ventricle stroke work to pressure volume area ratio (SW/PVA) was also calculated. Results In the overall cohort, 24 patients (39%) were VO 2 responders, and 48 patients had high ventriculo-arterial (E A /E V ) coupling ratio with a median value of 1.9 (1.6–2.4). Most of those patients were classified as VO 2 responders (28 of 31 patients, p = 0.031). Changes in VO 2 were correlated with those of indexed total peripheral resistances, E A , E A /E V and cardiac output. E A /E V ratio predicted VO 2 increase with an AUC of 0.76 [95% CI: 0.62–0.87]; p = 0.001. In principal component analyses, E A /E V and SW/PVA ratios were independently associated ( p < 0.05) with VO 2 response following interventions. Conclusions VO 2 responders were characterized by baseline high ventriculo-arterial coupling ratio due to high E A and low E V . Baseline E A /E V and SW/PVA ratios were associated with VO 2 changes independently of the hemodynamic intervention used. These results underline the pathophysiological significance of measuring ventriculo-arterial coupling in patients with hemodynamic instability, as a potential therapeutic target.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202301300016120ZK.pdf 458KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:1次