期刊论文详细信息
Health and Quality of Life Outcomes
The patient enablement instrument for back pain: reliability, content validity, construct validity and responsiveness
B. Öberg1  P. Enthoven1  A. Abbott1  H. H. Lauridsen2  A. Molgaard Nielsen2  J. Hartvigsen2  A. Kongsted2 
[1] Department of Health, Medicine and Caring Sciences, Division of Prevention, Rehabilitation and Community Medicine, Unit of Physiotherapy, Linköping University;Department of Sports Science and Clinical Biomechanics, University of Southern Denmark;
关键词: Validity;    Reliability;    Primary care;    Low back pain;    Outcome assessment;   
DOI  :  10.1186/s12955-021-01758-0
来源: DOAJ
【 摘 要 】

Abstract Background Currently, there are no outcome measures assessing the ability of people with non-specific low back pain to self-manage their illness. Inspired by the ‘Patient Enablement Instrument’, we developed the Patient Enablement Instrument for Back Pain (PEI-BP). The aim of this study was to describe the development of the Patient Enablement Instrument for Back Pain (PEI-BP) and investigate content validity, construct validity, internal consistency, test–retest reliability, measurement error, responsiveness and floor and ceiling effects. Methods The PEI-BP consists of 6 items that are rated on a 0–10 Numeric Rating Scale. Measurement properties were evaluated using the COSMIN taxonomy and were based on three cohorts from primary care with low back pain: The content validity cohort (N = 14) which participated in semi-structured interviews, the GLA:D® Back cohort (N = 272) and the test–retest cohort (N = 37) which both completed self-reported questionnaires. For construct validity and responsiveness, enablement was compared to disability (Oswestry Disability Index), back pain beliefs (Brief Illness Perception Questionnaire), fear avoidance (Fear-Avoidance Beliefs Questionnaire—physical activity), mental health (SF-36), educational level and number of previous episodes of low back pain. Results The PEI-BP was found to have acceptable content validity, construct validity, reliability (internal consistency, test–retest reliability and measurement error) and responsiveness. The Smallest Detectable Change was 10.1 points illustrating that a patient would have to change more than 1/6 of the scale range for it to be a true change. A skewed distribution towards the high scores were found at baseline indicating a potentially problematic ceiling effect in the current population. Conclusions The PEI-BP can be considered a valid and reliable tool to measure enablement on people seeking care for non-specific LBP. Further testing of the PEI-BP in populations with more severe LBP is recommended. Trial registration: Not applicable.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:4次