Materials | |
Assessment of Force Retention between Milled Metallic and Ceramic Telescopic Crowns with Different Taper Angles Used for Oral Rehabilitation | |
DianaMaria Vranceanu1  CosminMihai Cotrut1  StefanAlexandru Ilas1  Florin Baciu2  RalucaMonica Comaneanu3  DoinaLucia Ghergic3  CarolineAdela Ingrid Fischer4  | |
[1] Department of Metallic Materials Science, Physical Metallurgy, Faculty of Materials Science and Engineering, University POLITEHNICA of Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania;Department of Strength Materials, Faculty of Industrial Engineering and Robotics, University POLITEHNICA of Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania;Faculty of Dental Medicine, “Titu Maiorescu” University, 67A Gh. Petrascu Street, 040441 Bucharest, Romania;Organizing Institution of University Doctoral Studies, Doctoral School of Dentistry, “Titu Maiorescu” University, 67A Gh. Petrascu Street, 040441 Bucharest, Romania; | |
关键词: telescopic crowns; cobalt chromium alloy; zirconia; retention forces; computer-aided design/computer-aided manufacturing (CAD/CAM); | |
DOI : 10.3390/ma13214814 | |
来源: DOAJ |
【 摘 要 】
The present study assessed the retention forces corresponding to different telescopic systems used in removable prosthetic dentures. The telescopic systems were represented by Co–Cr alloy or zirconia-based primary crowns and Co–Cr secondary crowns. All crowns were manufactured using computer-aided design/computer-aided manufacturing technology (CAD/CAM). Two types of reference abutment teeth (upper canine and first upper molar) were selected in order to obtain the telescopic crowns and two taper angles—of 0° and 2°—were used for the design of the crowns. A number of 120 samples of telescopic crowns were obtained and subjected to mechanical tests, following a specific protocol, on a mechanical testing equipment. The retention of the telescopic systems was evaluated for different sets of cycles (up to 360), represented by movements that simulate the intraoral insertion and disinsertion of the telescopic systems. The present study highlights that the telescopic systems in which the primary crown is made of zirconia ceramics presents more advantages than those made of Co–Cr. All telescopic systems studied, highlighted that by modifying the taper angle from 0° to 2°, the retention forces have decreased, irrespective of the materials used for the fabrication of the primary crown, suggesting that by using a taper angle of 0°, which is known to be ideal, more efficient, and reliable prosthesis can be developed. Thus, even though the ceramic–metallic telescopic system exhibited the highest retention, all telescopic crowns evaluated registered values between 2–7 N, indicating that they are suitable for clinical use.
【 授权许可】
Unknown