期刊论文详细信息
Journal of Structural and Construction Engineering
Behaviour Verification of Gas Transfer Buried Steel Pipelines by Propagation of Seismic Waves in Soil Types
Jamal Ahmadi1  Reza Rasti2  Ali Nankeli3  Ali Goharrokhi4 
[1] Asistant Prof., Faculty of Engineering., University of Zanjan;Asistant Prof., Structure Eng. Dept., Faculty of Civil Eng., Shahid Beheshti Modares University;M.Sc. of Structure Engineering, Faculty of Engineering., University of Zanjan;university of zanjan;
关键词: vital arteries;    maximum strain;    buried pipe;    accelerogram;    seismic behaviour;   
DOI  :  10.22065/jsce.2018.99586.1338
来源: DOAJ
【 摘 要 】

The most important parameter for determining the level of performance and breakdown of buried pipes in the case of earthquake is the maximum value of strain. Vital arteries code, while studying the maximum value of strain, have addressed the seismic behavior of buried pipelines. Static methods don’t have the ability to consider the transient strain effect in their results, so it is necessary to consider another method in determining maximum strain. From the suggested methods to determine the maximum strain in buried pipes during earthquake is nonlinear dynamic analysis of pipes and the soil around it. In this study, using Abaqus software, we have presented a method to calculate the maximum strain of buried steel pipes for gas transfer in soil according to the parameters including earthquake energy like Arias intensity and Housner spectral intensity and using accelerograms. Analyses performed according to dynamic method is nonlinear and modeling has been done for three different lengths of gas transfer buried steel pipes in soil, with the internal pressure using different accelerograms for types of soil in Iran 2800 code. Then, in order to present a united relation to show the relationship between maximum strain of steel pipes and parameters including earthquake energy, in order to apply the considered relation for buried pipes with different lengths and different soils, we have used T/L parameter and the values of a and b (coefficients of fitted diagrams) in each section is expressed according to this parameter

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:3次