Engineering Science and Technology, an International Journal | |
Sources of vibration and their treatment in hydro power stations-A review | |
Ripul Ghosh1  Aparna Akula1  Rati Kanta Mohanta2  Thanga Raj Chelliah2  Srikanth Allamsetty3  | |
[1] Central Scientific Instruments Organization (CSIR-CSIO), Chandigarh, India;Hydro-Electric Systems Group, Dept. of Water Resources Development and Management, Indian Institute of Technology Roorkee, India;School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, India; | |
关键词: Vibration condition monitoring; Vibration monitoring; Health conditioning; Health monitoring; Hydro power plants; Electrical and mechanical equipment; | |
DOI : 10.1016/j.jestch.2016.11.004 | |
来源: DOAJ |
【 摘 要 】
Vibration condition monitoring (VCM) enhances the performance of Hydro Generating Equipment (HGE) by minimizing the damage and break down chances, so that equipment stay available for a longer time. The execution of VCM and diagnosing the system of an HPS includes theoretical and experimental exploitation. Various studies have made their contribution to find out the vibration failure mechanism and incipient failures in HPS. This paper gives a review on VCM of electrical and mechanical equipment used in the HPS along with a brief explanation of vibration related faults considering past literature of around 30 years. Causes of the vibrations on rotating and non-rotating equipment of HPS have been discussed along with the standards for vibration measurements. Future prospectus of VCM is also discussed.
【 授权许可】
Unknown