| Revue des Énergies Renouvelables | |
| Decoupling control of a series-connected two five-phase PMSM supplied by a three-level five-level inverter | |
| R.Taleb1  F.Mehedi2  L.Nezli2  M.O.Mahmoudi2  | |
| [1] Department of Electrical Engineering, Hassiba Ben Bouali, University of Chlef Hay Salem, National Roods N°19, 02000 Chlef, Algeria;Process Control Laboratory, PCL Ecole Nationale Polytechnique, ENP 10 Avenue Hasse Badi, B.P. 182, El Harrach, 16200 Algiers, Algerie; | |
| 关键词: multi-machine; permanent magnet synchronous machines (pmsms); series-connected; decoupling control; five-phase pmsm; three-level five-phase inverter; | |
| DOI : | |
| 来源: DOAJ | |
【 摘 要 】
This paper presents independent vector control of two five-phase permanent magnet synchronous machines, 'PMSMs' series-connected fed by a three-level five-phase inverter. Fully decoupled control of both machines is possible via an appropriate phase transposition while connecting the stator windings serial. The control system multi-machines classic based on vector control with conventional inverters comprise various problems are related to low power quality, pressure on motor bearing, etc. In this paper, decoupling control of a series-connected two five-phase PMSM powered by a three-level five-phase inverter is presented. Simulations results are presented and discussed for the whole system.