期刊论文详细信息
Civil Engineering Journal
SEISMIC ANALYSIS OF NUCLEAR POWER PLANT CANNED MOTOR PUMP UNIT BASED ON INTEGRAL CALCULATION METHOD
Li Bo1  Li Zhenggui1  Zhang Jiarong1  Yang Fengyu1  Li Muyu1  Liu Xiaobing1 
[1] Key Laboratory of Fluid and Power Machinery, Ministry of Education, Xihua University, Chengdu, 610039, China;
关键词: Nuclear power plant;    Canned motor pump;    Ansys integral calculation;    Earthquake spectrum analysis;   
DOI  :  10.14311/CEJ.2016.04.0026
来源: DOAJ
【 摘 要 】

The canned motor pump is a device in one of the most important loops in the nuclear power plant system and key technology research project, of which the seismic requirements shall be checked by Category A. It is required that the structural integrity and electric drive assembly performability of the unit can be ensured during or after operating basic earthquake (OBE) or safe shutdown earthquake (SSE). The author uses Ansys software workbench module to carry out appearance-based three-dimensional modeling, finite element meshing, intrinsic mode analysis, and carry out structural overall element analysis and calculation considering dead weight load and earthquake spectrum load. The results show that the unit major structure rotary and static parts, gear system, bearing parts, bolt and screw strengths meet the requirements and the structure maintains integrity, the relative deformation of the unit rotary and static parts shall be less than the specified value of gap among them, so as to keep the performability and not interfere with the operation. The appearance–based seismic analysis method not only can ensure the calculation accuracy, but also can greatly reduce the workload in calculation and checking, has a certain learning value.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:2次