期刊论文详细信息
Frontiers in Veterinary Science
Preliminary Outcome of a Novel Edge-to-Edge Closure Device to Manage Mitral Regurgitation in Dogs
Liujun Jia1  Xueying Zhou2  Jing Li2  Fangyu Zheng2  Bo Liu2  Wenzhi Pan3  Stacey B. Leach4 
[1] Beijing Key Laboratory of Pre-Clinic Research and Evaluation for Cardiovascular Implant Materials, Fuwai Hospital National Cardiovascular Centre, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China;College of Veterinary Medicine, China Agricultural University, Beijing, China;Department of Cardiology, Shanghai Institute of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai, China;Department of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO, United States;
关键词: canine;    mitral valve;    myxomatous degeneration;    transapical;    valve surgery;   
DOI  :  10.3389/fvets.2020.597879
来源: DOAJ
【 摘 要 】

Background: Veterinary management of mitral valve regurgitation due to mxyomatous valve disease in dogs is limited to medical treatments, which only postpones the onset of congestive heart failure or alleviates clinical symptoms. Most surgical procedures to manage this condition in humans require cardiopulmonary bypass and have a high risk of complications.Animals: Eight dogs with naturally occurring mitral valve regurgitation.Methods: Prospective observational study. All dogs were treated with a novel edge-to-edge transcatheter device named ValveClamp. The total surgical procedural time and total catheterization time were recorded. Echocardiographic variables measured pre- and post-procedure were compared using Wilcoxin-signed rank test with a P < 0.05 considered significant. Data were expressed as median and interquartile range and absolute numbers and percentages.Results: The procedural success rate was 100% and all the dogs survived without complications. The median (interquartile range) total surgical procedural time was 86.5 (76–96.2) minutes and catheterization time was 23.5 (22–33.8) minutes. Echocardiography revealed a significant reduction in mitral regurgitation severity in all dogs following the procedure based on both a reduced mitral regurgitant maximum jet area (P = 0.012) and a reduced mitral regurgitant maximum jet area to left atrial area (P = 0.018).Conclusion: The ValveClamp device is effective at reducing the severity of mitral regurgitation in dogs with naturally occurring myxomatous valve disease.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次