期刊论文详细信息
Sustainability
The Effects of Infilled Walls on Seismic Performance of RC Frame Structures with Eccentrically Placed Open Corridor
Bo Chen1  Xiao-Qing Fan2  Bo Wang3  Yue Xuan3  Xun Guo3 
[1] College of Civil Engineering, Nanjing Tech University, No.30, Puzhu South Rd., Nanjing 211816, China;Institute of Geophysics, China Earthquake Administration, No.5, University of Minzu South Rd., Beijing 100081, China;Key Laboratory of Building Collapse Mechanism and Disaster Prevention, Institute of Disaster Prevention, China Earthquake Administration, No.465, Xueyuan Rd., Langfang 065201, China;
关键词: RC frame;    earthquake;    shaking table;    infilled walls;    eccentrically placed open corridor;   
DOI  :  10.3390/su14095299
来源: DOAJ
【 摘 要 】

In this paper, an RC frame model with infilled walls was built and tested, including by a modal test, percussion test and shaking table test, the prototype of which was a collapsed teaching building with an eccentrically placed open corridor during the Wenchuan Earthquake in Xuankou Middle School. The natural frequency of the model was obtained by microseism testing, and the contribution of the infilled walls with different openings to the lateral stiffness of the model was discussed. In addition, the damping ratio, strain responses and internal force distribution of the columns were analysed by knocking the roof of the RC frame model, and then a shaking table test was conducted to study the seismic performance of the model. The results show that the value of longitudinal fundamental frequency increased from 1.88 Hz to 6.65 Hz, and the transverse one increased from 1.90 Hz to 13.40 Hz. The torsion frequency was increased by 6.65 times compared with that when the wall was not built. Furthermore, the damping ratio of the model was significantly increased after the infilled walls were built. When the floor moves longitudinally, the strain at the end of the columns restrained by semi-high continuous infilled walls is 2–4 times that in the unconstrained columns, and the shear force in the restrained columns is 4–8 times that in the unstrained columns. As a result, plastic hinges would form in the constrained columns; then, the columns would lose their vertical load capacity.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次