期刊论文详细信息
Case Studies in Thermal Engineering
Equivalent temperature prediction for concrete-filled cold-formed steel (CF-CFS) built-up column sections (part B)
Hélder D. Craveiro1  Aldina Santiago1  Rui A. Simões2  Rohola Rahnavard2 
[1] University of Coimbra, ISISE, Department of Civil Engineering, Coimbra, Portugal;Corresponding author.;
关键词: Concrete inner core;    Concrete outer core;    Equivalent temperature;    Embedded steel area;    Heat transfer analysis;   
DOI  :  
来源: DOAJ
【 摘 要 】

Innovative concrete-filled cold-formed steel (CF-CFS) built-up column sections subjected to axial compression and elevated temperatures were previously investigated, assessing their structural fire performance. However, the analytical fire resistance methodology presented in the EN1994-1-2 requires advanced heat transfer analysis to compute the temperature evolution of the steel and concrete components of the composite cross-section. This paper presents a set of empirical formulations to predict equivalent temperature for steel and concrete components of CF-CFS built-up column sections. The finite element modeling technique to predict temperature evolution through the CF-CFS built-up column sections was calibrated using a 2-D heat transfer analysis (part A of this study). As a simplification, the concrete infill was divided into two areas, namely inner and outer core areas. The equivalent temperature of the steel section and the steel embedded area were also considered. The results showed good accuracy of the proposed empirical formulas.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:4次