期刊论文详细信息
Sensors
Abdominal Stiffness Evaluation in Massage for Constipation
Mikako Yoshida1  Tetsuyou Watanabe2  Miho Shogenji3  Yunyi Wang4  Chiaki Sakakibara5 
[1] Department of Women’s Health Nursing & Midwifery, Tohoku University Graduate School of Medicine, Sendai 980-8575, Japan;Faculty of Frontier Engineering, Institute of Science and Engineering, Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan;Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa 920-0942, Japan;Graduated School of Natural Science and Technology, Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan;Home-Visit Nursing Care Station Yayanoie, 88 Suehiro, Komatsu 923-0954, Japan;
关键词: abdominal stiffness;    abdominal massage;    stiffness sensor;   
DOI  :  10.3390/s21041192
来源: DOAJ
【 摘 要 】

According to the experience of nurses and physiotherapists, the abdomen of constipated people becomes softer after abdominal massage. However, the relationship between the decrease in abdominal stiffness and the benefits of abdominal massage has not been examined quantitatively and is unclear. Furthermore, devices for measuring stiffness have been designed to measure relatively hard areas such as the shoulders and do not take into account the lateral outflow of the target tissue, which can be a problem when measuring the stiffness of soft areas such as the abdomen. To address these issues, this study presents a stiffness sensor suitable for measuring abdominal stiffness and investigates the relationship between the reduction in abdominal stiffness and the benefits of abdominal massage. The solution to prevent the lateral outflow of the target is the realization of a stopper, including a contact detection device, which enables a wide-area contact around the targeted area. The sensor consists of a stopper, probe, spring, and time-of-flight (ToF) sensors. The probe and spring provide appropriate pressure and deformation to the abdomen, whereas the stopper prevents the probe from being pushed into the abdomen more than necessary. The ToF sensor measures the deformation length when the deformation is stopped by the stopper. The abdominal stiffness can be derived from the deformation length. The investigation results indicate that the reduction in abdominal stiffness corresponds to the improvement of the stool condition or the maintenance of a healthy stool condition, whereas the maintenance of abdominal stiffness indicates the maintenance or deterioration of the stool condition.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次