期刊论文详细信息
Sustainable Environment Research
Effect of COD:N ratio on biological nitrogen removal using full-scale step-feed in municipal wastewater treatment plants
Pongsak Noophan1  Supaporn Phanwilai1  Kwang-Ho Choo2  Chi-Wang Li3 
[1] Department of Environmental Engineering, Faculty of Engineering, Kasetsart University;Department of Environmental Engineering, Kyungpook National University;Department of Water Resources and Environmental Engineering, Tamkang University;
关键词: Biological nitrogen removal;    COD:N;    Full-scale;    Step-feed;   
DOI  :  10.1186/s42834-020-00064-6
来源: DOAJ
【 摘 要 】

Abstract This study investigated the effect of low and high chemical oxygen demand (COD):N ratios on biological nitrogen removal and microbial distributions in full-scale step-feed (SF) municipal wastewater treatment plants (WWTPs) in Thailand (SF1) and Taiwan (SF2). The SF1 WWTP had a low COD:N (4:1) ratio, a long solids retention time (SRT) (> 60 d), and low dissolved oxygen (DO) conditions (0.2 mg L− 1 in anoxic tank and 0.9 mg L− 1 in aerobic tank). The total nitrogen (TN) removal efficiency was 48%. The SF2 WWTP had a high COD:N (10:1) ratio, a short SRT (7 d), and high DO (0.6 mg L− 1 in anoxic tank and 1.8 mg L− 1 in aerobic tank). The TN removal efficiency was 61%. The nitrification and denitrification rates from these two plants were inadequate. Using a quantitative polymerase chain reaction (qPCR) technique, the populations of ammonium oxidizing bacteria (AOB) and ammonium oxidizing archaea were quantified. Measurement of ammonia monooxygenase (amoA) gene abundances identified these AOB: Nitrosomonas sp., Nitrosospira sp., Nitrosoccus sp. and Zoogloea sp. Higher amounts of the archaeal-amoA gene were found with long SRT, lower DO and COD:N ratios. Abundance of Nitrobacter sp. was slightly higher than Nitrospira sp. at the SF1, while abundance of Nitrobacter sp. was two orders of magnitude greater than Nitrospira sp. at the SF2. More denitrifying bacteria were of the nirS-type than the nirK-type, especially at higher COD:N ratio. Most bacteria belong to the phyla Acidobacteria, Actinobacteria Bacteroidetes, Chloroflexi, Proteobacteria. The results from this work showed that insufficient carbon sources at the SF1 and high DO concentration in anoxic tank of SF2 adversely affected nitrogen removal efficiencies. In further research work, advanced techniques on the next generation sequencing with different variable regions should be recommended in full-scale WWTPs.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次