期刊论文详细信息
Journal of Clinical Medicine
Application of Three-Dimensional Computed Tomography Improved the Interrater Reliability of the AO/OTA Classification Decision in a Patellar Fracture
Yong-Bum Joo1  Jae-Ang Sim2  Ji-Wan Kim3  Seong-Eun Byun4  Wonchul Choi4  Young-Gon Na5  Oog-Jin Shon6 
[1] Department of Orhopaedic Surgery, Chungnam National University Hospital, Daejeon 35015, Korea;Department of Orhopaedic Surgery, Gil Medical Center, Gachon University College of Medicine, Incheon 21565, Korea;Department of Orthopaedic Surgery, Asan Medical Center, College of Medicine, University of Ulsan, Seoul 05505, Korea;Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University, Seongnam 13497, Korea;Department of Orthopaedic Surgery, Seoul Segyero Hospital, Seoul 05790, Korea;Department of Orthopedic Surgery, Yeungnam University Medical Center, Daegu 42415, Korea;
关键词: patella;    patellar fracture;    interrater reliability;    AO/OTA classification;    three-dimensional computed tomography;    3-D CT;   
DOI  :  10.3390/jcm10153256
来源: DOAJ
【 摘 要 】

We investigated whether interrater reliabilities of the AO/OTA classification of patellar fracture change with the imaging modalities applied, including plain radiography and two- and three-dimensional (2-D and 3-D) computed tomography (CT). Seven orthopedic specialists and four orthopedic residents completed a survey of 50 patellar fractures to classify the fractures according to the AO/OTA classification for patellar fractures. Initially, the survey was conducted using plain radiography only, then with 2-D CT introduced three weeks later and 3-D CT introduced six weeks later. Fleiss’ Kappa coefficients were calculated to determine interrater reliability. The overall interrater reliability of the AO/OTA classifications was 0.40 (95% CI, 0.38–0.42) with plain radiography only and 0.43 (95% CI, 0.41–0.45) with the addition of 2-D CT. With the addition of 3-D CT, the reliability was significantly improved to 0.54 (95% CI, 0.52–0.56). In specialists, interrater reliability of the classifications was moderate with all three imaging modalities. With the use of 3-D CT, interrater reliability of the classification was 0.53 (95% CI, 0.50–0.56), which was significantly higher than that with the use of 2-D CT (κ = 0.45; 95% CI, 0.42–0.48). In residents, interrater reliability of the classification was 0.30 (95% CI, 0.24–0.36) with plain radiography. The reliability improved to 0.49 (95% CI, 0.43–0.56) with the addition of 2-D CT, which was significantly higher than that with plain radiography only. The use of 3-D CT imaging improved interrater reliability of the classification. Therefore, surgeons, especially residents, may benefit from using 3-D CT imaging for classifying and planning the treatment of patellar fractures.

【 授权许可】

Unknown   

  文献评价指标  