期刊论文详细信息
Journal of Clinical Medicine
Kidney Perfusion in Contrast-Enhanced Ultrasound (CEUS) Correlates with Renal Function in Living Kidney Donors
Katja Kotsch1  Arne Sattler1  Klemens Budde2  Lutz Liefeldt2  Thomas Fischer3  Markus H. Lerchbaumer3  Bernd Hamm3  Thorsten Schlomm4  Andreas Maxeiner4  Kurt Miller4  Frank Friedersdorff4  Nasrin El-Bandar4  Robert Peters4 
[1] Department of General, Visceral and Vascular Surgery, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, 10117 Berlin, Germany;Department of Nephrology and Internal Intensive Care Medicine, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, 10117 Berlin, Germany;Department of Radiology, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, 10117 Berlin, Germany;Department of Urology, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, 10117 Berlin, Germany;
关键词: Contrast-enhanced ultrasound;    kidney perfusion;    kidney function;    kidney transplantation;    kidney donation;   
DOI  :  10.3390/jcm11030791
来源: DOAJ
【 摘 要 】

Contrast-enhanced ultrasound (CEUS) is a widely used diagnostic tool for analyzing perfusion and characterizing lesions in several organs. However, to date, it has not been sufficiently investigated whether there is an association between CEUS findings and kidney function. This study aimed at identifying the potential relationship between kidney function and the renal perfusion status determined by CEUS in living kidney donors. A total of 30 living kidney donors examined between April 2018 and March 2020 were included in the study. All patients underwent various diagnostic procedures for evaluation of renal function. CEUS was performed in all 30 donors one day before nephrectomy. Kidney perfusion was quantified using a postprocessing tool (VueBox, Bracco Imaging). Various perfusion parameters were subsequently analyzed and compared with the results of the other methods used to evaluate kidney function. Of all parameters, mean signal intensity (MeanLin) had the strongest correlation, showing significant correlations with eGFR (CG) (r = −0.345; p = 0.007) and total kidney volume (r = −0.409; p = 0.001). While there was no significant correlation between any perfusion parameter and diethylenetriaminepentaacetic acid (DTPA), we detected a significant correlation between MeanLin and DTPA (r = −0.502; p = 0.005) in the subgroup of normal-weight donors. The results indicate that signal intensity in CEUS is associated with kidney function in normal-weight individuals. Body mass index (BMI) may be a potential confounder of signal intensity in CEUS. Thus, more research is needed to confirm these results in larger study populations.

【 授权许可】

Unknown   

  文献评价指标  