期刊论文详细信息
RILEM Technical Letters
Wide-range optical pH imaging of cementitious materials exposed to chemically corrosive environments
Birgit Ungerböck1  Christoph Staudinger1  Sergey M Borisov1  Johanna Breininger1  Marlene Sakoparnig1  Viktor Schallert1  Florian Mittermayr1  Martin Dietzel1  Cyrill Grengg1  Torsten Mayr1  Bernhard Müller2 
[1] ;Graz University of Technology;
关键词: optical pH sensors;    surface pH;    pH-sensitive dyes;    concrete carbonation;    bio-corrosion;   
DOI  :  10.21809/rilemtechlett.2018.72
来源: DOAJ
【 摘 要 】

The pH of concrete-based material is a key parameter for the assessment of its stability and durability, since a change in pH is usually associated with major types of chemical degradation such as carbonation, leaching and acid attacks. Conventional surface pH measurements with potentiometric flat surface electrodes have low spatial resolution, whereas optical pH visualization with indicator dyes (phenolphthalein) only indicates the areas with higher or lower pH than the pKa of the indicator. In this regard, it is key to develop wide-range imaging systems, enabling accurate and spatially resolved determination of pH variability for an advanced knowledge of degradation mechanisms. This contribution presents the enhancements made for a high-resolution optical pH imaging system based on fluorescent aza-BODIPY indicator dyes. The measurement range was increased to 6 pH units (pH 6.5 to pH 12.5) by a combination of two indicator dyes. Moreover, background scattering effects were sufficiently eliminated. With the improved sensor foils steep pH gradients (up to 3 pH units within 2 mm) were successfully recorded in various concrete specimens using a macro lens reaching a resolution of down to 35 µm per pixel.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次