In this paper, an integrated transformer design methodology for dual-active-bridge (DAB) converters, which basically utilize leakage inductance so as to substitute a cumbersome inductor in the conventional DAB converters, is newly proposed. The proposed integrated transformer with integrated leakage inductance inherently includes leakage inductance and magnetizing inductance, whose values can be appropriately selected by modulating the number of turns and the center-core air-gap. Based on the theoretical analysis of the DAB converters, the major parameters, i.e., primary and secondary current levels and its phase difference, can be derived, and these values are utilized for magnetic analysis of the proposed integrated transformer. Considering core loss and copper loss of the proposed integrated transformer in the DAB converters, optimal values of the center-core air-gap