[1] Division of Cardiology Baylor School of Medicine and the Michael E. DeBakey VAMC Houston TX;Division of Cardiology Department of Medicine University of Washington Seattle WA;Division of Cardiology Pauley Heart CenterVirginia Commonwealth University Richmond VA;Harrington Heart and Vascular InstituteUniversity Hospitals Cleveland Medical Center Cleveland OH;Keele Cardiovascular Research Group Centre for Prognosis ResearchInstitute of Primary Care and Health SciencesKeele University Stoke‐on‐Trent United Kingdom;The Carl and Edyth Lindner Center for Research and Education, The Christ Hospital Cincinnati OH;The Heart Centre, RigshospitaletCopenhagen University Hospital Copenhagen Denmark;
关键词: aortic stenosis;    repositioning;    resheathing;    self‐expanding;    TAVI;    TAVR;   
DOI  :  10.1161/JAHA.121.024707
来源: DOAJ
【 摘 要 】

Background There is a concern that resheathing/repositioning of transcatheter heart valves during transcatheter aortic valve implantation (TAVI) may lead to an increased risk of periprocedural complications. We aimed to evaluate the short‐ and long‐term impact on clinical outcomes of resheathing for repositioning of transcatheter heart valves during TAVI procedures. Methods and Results We conducted a systematic search of Embase, MEDLINE, and Cochrane Central Register of Controlled Trials databases to identify studies comparing outcomes between patients requiring resheathing/repositioning during TAVI and those who did not. Random‐effects meta‐analyses were used to estimate the association of resheathing compared with no resheathing with clinical outcomes after TAVI. Seven studies including 4501 participants (pooled mean age, 80.9±7.4 years; 54% women; and 1374 [30.5%] patients requiring resheathing/repositioning) were included in this study. No significant differences between the 2 groups were identified with regards to safety: 30‐day mortality (n=3125; odds ratio [OR], 0.74 [95% confidence interval [CI], 0.41–1.33]; I2=0%), stroke (n=4121; OR, 1.09 [95% CI, 0.74–1.62]; I2=0%), coronary obstruction (n=3000; OR, 2.35 [95% CI, 0.17–33.47]; I2=75%), major vascular complications (n=3125; OR, 0.92 [95% CI, 0.66–1.33]; I2=0%), major bleeding (n=3125; OR, 1.13 [95% CI, 0.94–2.01]; I2=39%), acute kidney injury (n=3495; OR, 1.30 [95% CI, 0.64–2.62]; I2=44%), and efficacy outcomes: device success (n=1196; OR, 0.77 [95% CI, 0.51–1.14]; I2=0%), need for a second valve (n=3170; OR, 2.86 [95% CI, 0.96–8.48]; I2=62%), significant (moderate or higher) paravalvular leak (n=1151; OR, 1.53 [95% CI, 0.83–2.80]; I2=0%), and permanent pacemaker implantation (n=1908; OR, 1.04 [95% CI, 0.68–1.57]; I2=58%). One‐year mortality was similar between groups (n=1972; OR, 1.00 [95% CI, 0.68–1.47]; I2=0%). Conclusions Resheathing of transcatheter heart valves during TAVI is associated with similar periprocedural risk compared with no resheathing in several patient‐important outcomes. These data support the safety of current self‐expanding transcatheter heart valves with resheathing features. Registration URL: https://www.crd.york.ac.uk/prospero/; Unique identifier: CRD42021273715.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次