Water Science and Engineering | |
Similarity criterion of flood discharge atomization | |
Chen Huiling1  Zhou Hui2  Zhou Jie2  Wu Shiqiang2  Wu Xiufeng2  | |
[1] Hydraulic Engineering Department, Nanjing Hydraulic Research Institute, Nanjing 210029, P. R. China;State Key Laboratory of Hydrology-Water Resources and Hydraulic Engineering, Nanjing Hydraulic Research Institute, Nanjing 210029, P. R. China; | |
关键词: flood discharge atomization; scale effect; physical model test; Wujiangdu Hydropower Station; | |
DOI : 10.3882/j.issn.1674-2370.2008.02.006 | |
来源: DOAJ |
【 摘 要 】
By combining the results of prototype observation of flood discharge atomization at the Wujiangdu Hydropower Station, and by adopting the serial model test method, the model scale effect was examined, the influences of the Reynolds and Weber numbers of water flow on the rain intensity of flood discharge atomization were analyzed and a rain intensity conversion relation was established. It is demonstrated that the level of atomization follows the geometric similarity relations and it is possible to ignore the influence of the surface tension of the flow when the Weber number is greater than 500. Despite limitations such as incomplete data sets, it is undoubtedly helpful to study the scale effect of atomization flow, and it is beneficial to identify the rules of the model test results in order to extrapolate to prototype prediction.
【 授权许可】
Unknown