期刊论文详细信息
Frontiers in Oncology
A Megavoltage CT Image Enhancement Method for Image-Guided and Adaptive Helical TomoTherapy
Yong Yin1  Yang Cheng1  Haining Yu1  Baosheng Li1  Chenxi Yue2  Jiwen Dong2  Yaru Liu2  Jian Zhu3 
[1] Department of Radiation Oncology, Shandong Cancer Hospital, Shandong University, Jinan, China;Network-Based Intelligent Computing, University of Jinan, Jinan, China;Shandong Key Laboratory of Digital Medicine and Computer Assisted Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China;
关键词: megavoltage CT;    image guided radiotherapy;    adaptive radiotherapy;    tomotherapy;    image enhancement;    block matching;   
DOI  :  10.3389/fonc.2019.00362
来源: DOAJ
【 摘 要 】

Purpose: To propose a novel method to improve the mega-voltage CT (MVCT) image quality for helical TomoTherapy while maintaining the stability on dose calculation.Materials and Methods: The Block-Matching 3D-transform (BM3D) and Discriminative Feature Representation (DFR) methods were combined into a novel BM3D + DFR method for their respective advantages. A phantom (Catphan504) and three serials of clinical (head & neck, chest, and pelvis) MVCT images from 30 patients were acquired using the helical TomoTherapy system. The contrast-to-noise ratio (CNR) and edge detection algorithm (canny) was employed for image quality comparisons between the original and BM3D + DFR enhanced MVCT. A simulated rectangular field of 6 MV X-ray beams were vertically delivered on the original and post-processed MVCT serials of the same CT density phantom, and the dose curves on both serials were compared to test the effects of image enhancement on dose calculation accuracy.Results: In total, 466 transversal MVCT slices were acquired and processed by both BM3D and the proposed BM3D + DFR methods. Compared to the original MVCT image, the BM3D + DFR method presented a remarkable improvement in terms of the soft tissue contrast and noise reduction. For the phantom image, the CNR of the region of interest (ROI) was improved from 1.70 to 4.03. The average CNR of ROIs for 10 patients from each anatomical group, were increased significantly from 1.45 ± 1.51 to 2.09 ± 1.68 for the head & neck (p < 0.001), from 0.92 ± 0.78 to 1.36 ± 0.85 for the chest (p < 0.001), and from 1.12 ± 1.22 to 1.76 ± 1.31 for the pelvis (p < 0.001), respectively. The canny edge detection operator showed that BM3D + DFR provided clearer organ boundaries with less chaos. The root-mean-square of the dosimetry difference on the iso-center passed horizontal dose profile curves and vertical percentage depth dose curves were only 0.09% and 0.06%, respectively.Conclusions: The proposed BM3D + DFR method is feasible to improve the soft tissue contrast for the original MVCT images with coincidence in dose calculation and without compromising resolution. After integration in clinical workflow, the post-processed MVCT may be better applied on image-guided and adaptive helical TomoTherapy.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次