期刊论文详细信息
Materials
Impact of Self-Compacting Concrete Admixtures on Frost Resistance and Compressive Strength—Commensurability of Frost Resistance Criteria
Beata Łaźniewska-Piekarczyk1  Adam Piekarczyk2 
[1] Department of Building Processes and Building Physics, Faculty of Civil Engineering, Silesian University of Technology, 44-100 Gliwice, Poland;Department of Building Structures, Faculty of Civil Engineering, Silesian University of Technology, 44-100 Gliwice, Poland;
关键词: concrete admixtures;    non-destructive testing;    internal frost resistance methods;    frost resistance criteria;    compressive strength;   
DOI  :  10.3390/ma14112922
来源: DOAJ
【 摘 要 】

The article presents the results of original and relevant tests from the point of view of using self-compacting concrete admixtures, especially their compatibility with the cement and mutual compatibility in the case of using several admixtures in one mixture. The research contributes to the recognition of the effect of an unintentionally air-entraining superplasticiser (SP), anti-foam (AFA), viscosity-modifying (VMA) and air-entraining (AEA) admixtures on the internal frost resistance and compressive strength of self-compacting concrete. Positive and undesirable effects of the combined use of several admixtures in this area have not been the subject of extensive analyses and publications so far. Superplasticiser, which unintentionally introduced a large amount of air to the concrete mixture, had a negative effect on the strength of the concrete and a positive effect on frost resistance. The addition of AFA to such concrete did not change the strength but worsened the values of the parameters estimating frost resistance. The AEA admixture resulted in a decrease in the strength of concrete but contributed to a change in the tendency to weaken the frost resistance observed in non-air-entrained concrete. The article also deals with the problem of compliance of the frost resistance criteria estimated upon various measures. It may be disturbing that finding frost resistance based on one criterion does not always mean frost resistance on another criterion. The discrepancies can be significant and misleading.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次