期刊论文详细信息
Frontiers in Endocrinology
Predicting Vertebral Bone Strength Using Finite Element Analysis for Opportunistic Osteoporosis Screening in Routine Multidetector Computed Tomography Scans—A Feasibility Study
Jan S. Kirschke1  Michael Dieckmeyer1  Thomas Baum1  Maximilian T. Löffler1  Peter B. Noël2  Nithin Manohar Rayudu3  Karupppasamy Subburaj3 
[1] Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany;Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States;Engineering Product Development (EPD) Pillar, Singapore University of Technology and Design (SUTD), Singapore, Singapore;
关键词: multidetector computed tomography;    spine;    finite element analysis;    osteoporosis;    opportunistic screening;   
DOI  :  10.3389/fendo.2020.526332
来源: DOAJ
【 摘 要 】

PurposeTo investigate the feasibility of using routine clinical multidetector computed tomography (MDCT) scans for conducting finite element (FE) analysis to predict vertebral bone strength for opportunistic osteoporosis screening.MethodsRoutine abdominal MDCT with and without intravenous contrast medium (IVCM) of seven subjects (five male; two female; mean age: 71.86 ± 7.40 years) without any bone disease were used. FE analysis was performed on individual vertebrae (T11, T12, L1, and L2) including the posterior elements to investigate the effect of IVCM and slice thickness (1 and 3 mm) on vertebral bone strength. Another subset of data from subjects with vs. without osteoporotic vertebral fractures (n = 9 age and gender-matched pairs) was analyzed for investigating the ability of FE-analysis to differentiate the two cohorts. Bland-Altman plots, box plots, and coefficient of correlation (R2) were calculated to determine the variations in FE-predicted failure loads for different conditions.ResultsThe FE-predicted failure loads obtained from routine MDCT scans were strongly correlated with those from without IVCM (R2 = 0.91 for 1mm; R2 = 0.92 for 3mm slice thickness, respectively) and different slice thicknesses (R2 = 0.93 for 1mm vs. 3mm with IVCM). Furthermore, a good correlation was observed for 3mm slice thickness with IVCM vs. 1mm without IVCM (R2 = 0.87). Significant difference between FE-predicted failure loads of healthy and fractured patients was observed (4,705 ± 1,238 vs. 4,010 ± 1,297 N; p=0.026).ConclusionRoutine clinical MDCT scans could be reliably used for assessment of fracture risk based on FE analysis and may be beneficial for patients who are at increased risk for osteoporotic fractures.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次