期刊论文详细信息
Results in Materials
Study of an exhumed HDPE geomembrane used in an industrial water pond: Physical and thermoanalytical characterisations
Clever Aparecido Valentin1  Marcelo Kobelnik2  Fernando Luiz Lavoie3  Jefferson Lins da Silva4  Maria de Lurdes Lopes4 
[1] Corresponding author. Mauá Institute of Technology, São Caetano Do Sul, SP, Brazil.;University of São Paulo - USP, São Carlos School of Engineering, EESC, São Carlos, SP, Brazil;Mauá Institute of Technology, São Caetano Do Sul, SP, Brazil;University of São Paulo - USP, São Carlos School of Engineering, EESC, São Carlos, SP, Brazil;
关键词: High-density polyethylene;    TG;    DSC;    TMA;    Physical tests;   
DOI  :  
来源: DOAJ
【 摘 要 】

This paper analyzed the behavior of an HDPE geomembrane exhumed sample used for 2.25 years as a liner in an industrial water pond from a Brazilian company, as well as another similar sample as a reference. The thermogravimetry (TG) using different heating rates under synthetic air purge gas evaluation showed that the exhumed sample presented a different behavior in the TG curve for a heating rate of 5 ​°C min-1 attributed to the reaction time. The thermomechanical analysis (TMA) curves without purge gas showed the range of thermal stability between 30 and 65 ​°C for the reference sample, which is attributed to a molecular relaxation. The exhumed sample does not have the same relaxation, probably because this sample was submitted to severe environmental conditions in the field. Finally, the physical property values for the exhumed sample showed mechanical brittle behavior, which can indicate that changes probably occurred in the polymer structure.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:2次