期刊论文详细信息
Energies
Development of an Efficient Cooling Strategy in the Heading Face of Underground Mines
Houli Fu1  Xian Li1 
[1] School of Civil Engineering and Architecture, Linyi University, Linyi 276000, China;
关键词: heading face;    excavation roadway;    high-efficient cooling;    air cooler;    mine cooling system;   
DOI  :  10.3390/en13051116
来源: DOAJ
【 摘 要 】

Heat damage in deep mines is severe and can lead to adverse health effects. The existing refrigeration schemes for the heading face in excavation roadways aim to cool the whole cooling region. However, the ratio of the area occupied by workers to that of the cooling region is quite small. A great quantity of energy for refrigeration is doomed to waste. In this study, a new cooling strategy for building a non-uniform environment in the heading face was developed. A certain quantity of well-designed tracking air coolers were distributed in the excavation roadway near the heading face. The air cooler tracked the constantly moving workers and blew cold air to them. Economic analysis based on estimation of the cooling load for this cooling strategy was conducted. The airflow in the excavation roadway was numerically simulated to estimate the cooling effect. An average energy saving of approximately 30% could be realized. The thermal environment for the workers whether near the heading face or in the roadway improved. This cooling strategy should be considered in all of mine cooling.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次